Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-Beamlines  Not logged in ELOG logo
Message ID: 105     Entry time: Thursday, March 16, 2017, 15:50
Author: Keith C Ng 
Category: Primary Beamlines 
Type: Repair 
Subject: collimator b transition to t2 

On Monday found leaking joint was the ring directly downstream of T2. Vacuum group has been spraying Vacseal (http://www.vacseal.net/Pages/default.aspx) sealant over the last 3 days attempting to get it in between the flanges and have partial vacuum to draw in the fluid. Seven sprays have been completed as of March 16th.

Tomorrow, 2 more applications will be made and then Vacuum group will pump the T2 volume over the weekend.

Attachment 1: 20170316_collimatorb_RHB_8023.JPG  5.149 MB  | Hide | Hide all
20170316_collimatorb_RHB_8023.JPG
Attachment 2: 20170316_collimatorb_RHB_8025.JPG  4.970 MB  | Show | Hide all
ELOG V2.9.2-2455