Installed the blank off on the T2 M9 exit port:
Blank off 2013 installation procedure: 2.5 turns of the preload nut, after pins are engaged and springs are at free length.
Blank off 2015 installation procedure: 1.5 turns of the preload nut, after pins are engaged and springs are at free length. (one less turn for insurance?)
2017 (this year) installed blanking plate via hammering/tapping pins into place:
- Spring eyes were set at spring free length and then placed down
- Pins did not slide through eyes as was expected.
- Nuts were then backed off roughly 1 turn, then pins were lightly tapped down into place
- Nuts then turned back to zero/starting position
- Then alternating east west by .5 turn tightened to 1.5 turns, 1/2 turn indicated by half bar pen marking.
This year different than prior years due to tapping pins into place rather than backing off eyelet nuts and sliding pins into place *then* tightening to zero point and then tightening to preload.
Blank off installed at 11:15, vacuum group not able to pump on T2 until tomorrow. |