Message ID: 8     Entry time: Friday, December 05, 2014, 10:43
Author: Isaac Earle 
Category: 100KW Beam Dump 
Type: Development 
Subject: Lower Lead Shield Drain Line Installed 

A 1/8" SS tube was routed from the Swagelok fitting on the front of the lower lead shield to the service stand water catch tray as shown in the attached photos.

The tube was routed to fit in the cut-out and chamfered corner gaps of block TSH0387 in the de-rated EHDT shielding assembly TSH0293.