December 12, 2024 - Chad Fisher, Albert Kong, Aaron Tam 

Tests:

Gas lines removal: 

  • Starting with the most exterior connection, VCR connection loosened off with open ended conventional wrench
  • Once loose, the nut can be un threaded with manipulator finger (rolling nut technique) 
  • Once gas line unhooked, gasket removed by bringing female end outside the service tray footprint and jiggling until the gasket was removed
    • Also possible to use a pick if needed
  • The same procedure was conducted for the interior VCR connection

Gas lines installation: 

  • Starting with the inner most connection
  • Gasket placed on 3D printed tool and clipped into position on VCR male end
  • At first an M10 bolt was inserted into the elbow below VCR connection, but without rotational authority, the makeshift handle is not worth using
  • Griping the elbow with one manipulator and rolling the nut onto the threads with the other proved successful
  • Nut was tightened using conventional open ended 19mm wrench

Observations/Notes:

  • Service Tray was not in a fully connected position, so even less space will be afforded.
    • This may affect the ability to get 2 manipulators on the same connection
  • Piston modules were missing some limit wires on the side. These constrain movement horizontally and will either need to be removed as part of the procedure or, make the procedure more difficult
  • Mass markers and various other connectors not installed, and these could slightly restrict movement as well
  • Service tray pin was restricting the movement of the left manipulator during install
  • Lighting was inadequate under the piston 

Recommendations/follow up items/questions:

  • All metal Parker VGR style gaskets to replace plastic retainer versions
    • This is so that the degraded plastic doesn't break off and end up in the gas lines (upside down connections)
  • A modified wrench with flats for handles and with more length would make the above procedures easier 
  • Along with raising and lower the service tray, the service tray pin being oriented towards the beam entry direction, would make life easier 
  • Still need to test gasket install on "other" Piston gas line connection
    • Chad will redesign some new gasket tools to be tested
      • side load and axial load gaskets, low and high clearance, aluminum construction 
  • Lighting positioned to flood the service tray area will be needed
  • labeling the gas lines with a more permanent solution will be needed
  • Once the high voltage feed-through parts have come in, we can re-test and see if the piston module can be lowered to aid in target removal situations
  • Aaron will test Parker style seals to see if they can be removed as easily once brought up to specified torque 

------------------------------------------------------------------------------------------------------------------------------------------------------------------

 December 16, 2024

  • Upon inspecting the piston modules on AETE in TISA, we became aware of how the wires are arranged for the limit switches, it may be a good idea to look into how these wires are handled when using the piston module jig.
Attachment 1: exteriror_gas_line_removal.jpg  241 kB  | Show | Hide all
Attachment 2: Finger_rolling_off_nut.jpg  204 kB  | Show | Hide all
Attachment 3: gasket_sitting_on_current_tool.jpg  98 kB  | Hide | Hide all
gasket_sitting_on_current_tool.jpg
Attachment 4: Gasket_part_number.jpg  206 kB  | Show | Hide all
Attachment 5: Clearance_for_two_manipulator_grippers.jpg  155 kB  | Show | Hide all
Attachment 6: Clearance_for_two_manipulator_grippers2.jpg  191 kB  | Show | Hide all
Attachment 7: Clearance_for_two_manipulator_grippers3.jpg  189 kB  | Show | Hide all
Attachment 8: M10_Bolt_used_in_elbow.jpg  192 kB  | Show | Hide all
Attachment 9: Parker_VGR_Gasket_installed.jpg  141 kB  | Show | Hide all
Attachment 10: Some_trouble_with_gasket_tool.jpg  172 kB  | Show | Hide all
Attachment 11: trouble_with_conventional_wrench.jpg  219 kB  | Show | Hide all
Attachment 12: Interior_gas_line_torquing.jpg  217 kB  | Show | Hide all
Attachment 13: IMG_0845.JPEG  791 kB  Uploaded Monday, December 16, 2024, 17:09  | Show | Hide all
ELOG V2.9.2-2455