  5   Tuesday, September 06, 2011, 11:23 TaCTaC#1LP-SIS Laser cut TaC  

D-shape TaC, 18.5mm-14.5mm:  2 Casts were cut. 

Use file D-shape-car-1850

  1   Wednesday, March 23, 2011, 20:57     e-log checks out 

 test great - thank you very much for setting up the e-logs for the targets & ion sources group's hot-lab equipment

  2   Thursday, April 07, 2011, 15:46     Ta foils  

March 22, 2010:

More Ta foils are needed to make the backup Ta Hp surface (w.o#38295-4).  2 more sheets (9" x 11.5") of Ta foils (0.025mm thickness) were laser cut.   Making more stacks of Ta foils is in progress...

 

  3   Thursday, May 12, 2011, 16:16     SiC#26-HP-FEBIAD discs 

May2, 2011:  Laser cut SiC cast#1 but the size was wrong.  It turned out to be too large to fit in the target oven (21mm). 

May4, 2011:  Re-drew the laser drawing (currently saved in the desktop of TRILIS81) for 18.34mm in diameter.  It works perfectly!  Laser cut cast#2,3,4,5 for SiC#26.

 

  4   Monday, May 16, 2011, 17:55     SiC-HP-FEBIAD discs (spare target) 

Mon May 16 17:54:03 2011:  SiC cast#7, #6, #9, and #10 were laser cut at 18.50mm in diameter.  The discs are used for SiC-HP-FEBIAD Spare target.