  5   Tuesday, September 06, 2011, 11:23 TaCTaC#1LP-SIS Laser cut TaC  D-shape TaC, 18.5mm-14.5mm:  2 Casts
were cut. 
Use file D-shape-car-1850
  
  4   Monday, May 16, 2011, 17:55     SiC-HP-FEBIAD discs (spare target) Mon May 16 17:54:03 2011:  SiC cast#7,
#6, #9, and #10 were laser cut at 18.50mm
in diameter.  The discs are used for
  
  3   Thursday, May 12, 2011, 16:16     SiC#26-HP-FEBIAD discs May2, 2011:  Laser cut SiC cast#1
but the size was wrong.  It turned out
to be too large to fit in the target oven
  
  2   Thursday, April 07, 2011, 15:46     Ta foils  March 22, 2010:
More Ta foils are needed to make
the backup Ta Hp surface  (w.o#38295-4). 
  
  1   Wednesday, March 23, 2011, 20:57     e-log checks out  test great - thank you very much
for setting up the e-logs for the targets
& ion sources group's hot-lab equipment
  