Wednesday, June 18, 2025, 15:03
A boat wrapped in 3 Ta heatshields
Sintering S1.2s, S2.2s, bare Ta x2 (S0.2s)
Vacuum IGP1 initial = 1. 3e-06 Torr
Target temperature on OMEGA= 1850 C
OMEGA slope:= 0.990
Target time at max temperature = 4 hours
Final TGHT current= 420
1A/min to = 420 A TGHT
Good vacuum = 5.0 e-04 Torr
Bad vacuum = 5.0E-02 Torr
Thursday, June 19, 2025, 06:11
Starting ramp up at 1A/min
Set final value (A) to 420A
initial IGP1= 1. 3e-06 Torr
Thursday, June 19, 2025, 12:54
Set final current to 430A
Thursday, June 19, 2025, 13:27
Set final current to 435A
Thursday, June 19, 2025, 13:36
Set final current to 440A
Thursday, June 19, 2025, 13:41
Reached 431.4A and 1835C, holding for 4h
Thursday, June 19, 2025, 14:00
Ramped up to 1850 C on OMEGA
TGHT = 437.2 A on RD and Set to 446 A
TGHT = 7.6 V
Holding until 5:41 pm
Thursday, June 19, 2025, 18:16
Started rampdown at 540 pm @ -2A/min
Temperature was reading 1837 C on OMEGA |