Thursday, June 12, 2025, 12:33
A boat wrapped in 3 Ta heatshields
Sintering S1.1s, S2.1s, bare Ta x2 (S0.1s)
Vacuum IGP1 initial = 6.76 e-7 Torr
Target temperature on OMEGA= 1800-1900 C
OMEGA slope:= 0.990
Target time at max temperature = 4 hours
Final TGHT current= ~420A (adjustable)
1A/min to =400 A TGHT
Good vacuum = 5.0 e-04 Torr
Bad vacuum = 5.0E-02 Torr
Friday, June 13, 2025, 08:53
Set final value (A) to 400A
Set current increments (A) to 1A/min
Friday, June 13, 2025, 14:48
Slight increases in pressure apparent in graph - small peaks appeared
Friday, June 13, 2025, 16:00
Heating ramp stalled around 1760 C and 402A, started manually increasing to 1785 C and 410A
Friday, June 13, 2025, 16:10
Reached 1785 C and 410A
Friday, June 13, 2025, 20:12
OMEGA at 1785 C
Started rampdown @-2A/min
|