Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Evaporator_2  Not logged in ELOG logo
Message ID: 580     Entry time: Thursday, June 09, 2022, 09:09
Author: Darwin Ortiz Rosales 
Target Material: Ta 
Target Oven W.O#:  
Source: HP-FEBIAD 
Status: Done 
Subject: Troubleshooting 

Thursday, June 09, 2022, 09:07

Yesterday, Wednesday June 08, 2022 @ ~3.00 pm a "dummy" target container was installed in EVAP 2 after the heatshield assembly had been swapped.

The purpose is to test correct functioning of the system.  Melting and evaporation on one of the bolts of the previous target container (eLog578) prompted the change in heatshield assembly and current testing.

TGHT was ramped up to 740A @ 4A/min, left to run at the final current for ~4.5 hours and then ramped down @-2A/min to 0A.

Will dismount dummy container this morning.

IGP1=2.5e-07 Torr


Thursday, June 09, 2022, 11:16

The target appears in good shape.  No abnormal behaviour. 

Picture attached are of the previous failed target eLog 578

 

Attachment 1: MicrosoftTeams-image_(3).png  111 kB  Uploaded Thursday, June 09, 2022, 10:15  | Show | Hide all
Attachment 2: MicrosoftTeams-image_(4).png  91 kB  Uploaded Thursday, June 09, 2022, 10:15  | Show | Hide all
Attachment 3: MicrosoftTeams-image_(5).png  122 kB  Uploaded Thursday, June 09, 2022, 10:15  | Show | Hide all
ELOG V2.9.2-2455