Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Evaporator_2  Not logged in ELOG logo
Message ID: 18     Entry time: Tuesday, May 15, 2012, 14:00
Author: John Wong 
Target Material:  
Target Oven W.O#:  
Source:  
Status: Maintenance 
Subject: Installed a new stainless metal heat shield 

 Tuesday, May 15, 2012, 13:45

It was discovered that one of the insulators that supported the target module broke apart (see Attachment#1).  This might be caused by the heat from the target legs that reflected back from the base to the insulators.  The burnt marks are the evidence.  

A stainless metal sheet is used as the heat shield  (see Attachment #2). 


 

Attachment 1: Evaporator#2_broken_insulator.pdf  1.290 MB  | Show | Hide all
Attachment 2: Evaporator#2_upgrade_.pdf  1.419 MB  | Hide | Hide all
Evaporator#2_upgrade_.pdf
ELOG V2.9.2-2455