 Tuesday, May 15, 2012, 13:45

It was discovered that one of the insulators that supported the target module broke apart (see Attachment#1).  This might be caused by the heat from the target legs that reflected back from the base to the insulators.  The burnt marks are the evidence.  

A stainless metal sheet is used as the heat shield  (see Attachment #2). 


 

Attachment 1: Evaporator#2_broken_insulator.pdf  1.290 MB  | Hide | Hide all
Evaporator#2_broken_insulator.pdf
Attachment 2: Evaporator#2_upgrade_.pdf  1.419 MB  | Show | Hide all