Message ID: 34     Entry time: Wednesday, September 07, 2011, 13:41
Author: John Wong 
Target Material: TaC 
Target Oven W.O#: 38634-6 
Source: LP-SIS 
Status: Done 
Subject: TaC#1: Sintering and Organics burn-off  

Wednesday, September 07, 2011, 15:31

125 discs of TaC/C

Total discs mass = 125

Total length = 4.5mm

Total Mass = 30.41g

No Ta-heat shield. 

Left opening with D-TaC-sintered cap, and Right opening with regular TaC-sintered cap (orientation with the ionizer tube pointing out of the page).

Target is currently in the evaporator and being pumped down. 


Thursday, September 08, 2011, 09:13

Evaporator has been pumped down over night, IG1 currently at 1.74 e-6 Torr.   

Will begin TGHT, max @ 580A.

TGHT @ 50A, vac stable @ 1.7e-6 Torr.


Thursday, September 08, 2011, 10:18 

THGT @ 90A, pressure is increasing, currently at 4.7e-5 Torr and going up. 


 Thursday, September 08, 2011, 10:25

Auto-heating has begun. Set rate at 2A/min to max current 580A.

Incrementing if vac < 5.0 e-5 Torr, backing off if vac > 6.0 e-5 Torr. 


Friday, September 09, 2011, 07:58

TGHT auto cool down started @ 02:00, and at 0A.  IG currently @ 1.3e-6 Torr.  Venting chamber in progress.  Target will be removed from the evaporator afterward.

Target looks good :)  No signs of damage on the end cap or the target oven overall. 

See attachment 1 for the striptool. 

See attachment 2 and 3 for the target and endcaps after the sintering process.

 

Attachment 1: TaC#1.jpg  28 kB  Uploaded Friday, September 09, 2011, 11:41  | Show | Hide all
Attachment 2: endcaps_after_sintering.png  1.126 MB  Uploaded Friday, September 09, 2011, 11:42  | Hide | Hide all
endcaps_after_sintering.png
Attachment 3: TaC_aftersintering.jpg  1.147 MB  Uploaded Friday, September 09, 2011, 11:42  | Show | Hide all
ELOG V2.9.2-2455