Author: Marla Cervantes 
Target Material: Empty 
Target Oven W.O#: P2N-02  
Source:  
Status: Done 
Subject: P2N test#1 
The assembly consists of two tantalum foils, 0.001" thick, which are radially crimped to form a cylindrical surface. The outside support are two P2N  conditioning legs, and the inside supports are tantalum tapered rings. The solidworks geometry for this test is ITD0811 in PDM. 
 
A first current ramp up to 600 amperes on the bare naked target is attempted to benchmark the current/voltage increase in a bare target, so that we have reference values for future rampings with graphite and target material inside. 

Wednesday, January 22, 2020, 18:07

A P2N container  with no heat shields, and no graphite container was installed in the EVAP1

Chamber is currently being evacuated.


 Thursday, January 23, 2020, 09:45

Pressure IGP1=1.87e-6 Torr

Final desired current TGHT = 600 A

Manually tapped to 40 A

 The voltage looks ok, at 32 A the voltage's behavior change (see picture "voltage at 32 A") but is stable


Thursday, January 23, 2020, 13:20

Autoramp is set to 4/30s to 300 A 

The voltage and vacuum were stable so the autoramp was kept at 4/30s and the final current was set to 600 A

At 600 A the voltage was 2.4 V, the current and voltage remained stable for 1 hour (see figures 600A and 600A-zoomed)


Thursday, January 23, 2020, 15:57

The current was ramp down to 0 A  at -5A/20s 


Thursday, January 23, 2020, 16:36 

After 10 min at 0A, the current was ramp up to 600 A at 4A/30s.

At 600 A the voltage was 2.43 V (TGHT)

The container was left at 600 A overnight.


Friday, January 24, 2020, 10:51

The PN2 stayed at 600 A for 15 hrs

The voltage increased 0.1 V during the first 7hr at 600 A and then it stabilized at 2.5 V (see figure "second ramp voltage")


Friday, January 24, 2020, 10:57

The current was ramp down to 0A at -5A/20s  


 

Attachment 1: p2n_conditioning_-_Naked_target_installed.jpg  117 kB  Uploaded Thursday, January 23, 2020, 13:29  | Show | Hide all
Attachment 2: voltage_at_32_A.JPG  56 kB  Uploaded Thursday, January 23, 2020, 13:29  | Hide | Hide all
voltage_at_32_A.JPG
Attachment 3: 600A.JPG  61 kB  Uploaded Thursday, January 23, 2020, 15:54  | Show | Hide all
Attachment 4: 600A-zoomed.JPG  69 kB  Uploaded Thursday, January 23, 2020, 15:54  | Show | Hide all
Attachment 5: First_current_ramp_up.JPG  69 kB  Uploaded Thursday, January 23, 2020, 16:44  | Show | Hide all
Attachment 6: Second_ramp_voltage.JPG  150 kB  Uploaded Friday, January 24, 2020, 10:59  | Show | Hide all