Message ID: 228     Entry time: Tuesday, October 30, 2018, 10:17     Reply to this: 229
Author: Marla Cervantes 
Target Material: UC2 
Target Oven W.O#: 43044-7  
Source: LP-SIS 
Status: In progress 
Subject: UCx Fully loaded graphite insert thermal test - FL#1 

 Tuesday, October 30, 2018, 10:12

A new LP-SIS was coated and syntered (e-log 420 Evaporator_2) 

The container was loaded with a graphite insert loaded with UCx

Graphite insert + UCx mass = 26.927 g

A current of 440 A TGHT and 230 A TBHT will be inputed to the contianer


IGP1 = 8.72e-7 Torr

 The current was tapped manually to 440 A TGHT and 230 A TBHT (see fig. Heatinf test)

Maximum pressure during heating = 1.7e-3 Torr.

Target will stay at maximum current for 1 week.

 

Attachment 1: Heat_test.JPG  81 kB  Uploaded Wednesday, October 31, 2018, 11:11  | Show | Hide all