OLIS Logbook
General
General, Page 6 of 26
Not logged in
List
|
Find
|
Select
|
Import
|
Login
|
Help
New entries since:
Wed Dec 31 16:00:00 1969
Full
| Summary |
Threaded
513 Entries
Goto page
Previous
1
,
2
,
3
...
5
, 6,
7
...
24
,
25
,
26
Next
ID
Date
Author
Type
Category
Subject
Text
1
Thu May 14 11:07:33 2009
Hossein Rafighi
Test
Testing!
3
Fri May 15 14:12:45 2009
Geoff Wight
1st test
test
6
Fri May 22 12:31:36 2009
Raymond Dubé
Test
Hello world
67
Mon Jul 13 09:49:52 2009
Damien Gallop
18O4+ tuning to TIGRESS today
As per our agreed deal last week, today
is reserved for Supernanogan tuning to TIGRESS.
Development will resume tomorrow.
68
Mon Jul 13 17:19:29 2009
Damien Gallop
MCIS vacuum trip at ~15:30
An MCIS vacuum trip occurred somewhere
around 15:30. Sophia observed a drop-off
in beam. The cause looks like the PLC-related
69
Mon Jul 13 17:41:04 2009
Damien Gallop
Supernanogan development Monday morning
As noted, Keerthi was called to restart
the source after a power bump. He continued
Supernanogan development through the night
70
Tue Jul 14 09:47:14 2009
Damien Gallop
18O4+ tuning to TIGRESS this morning
We have a change of schedule. Due to circumstances,
Sophia will continue tuning to TIGRESS this
morning. Sgan Development will resume this
7x
71
Tue Jul 14 15:19:51 2009
Damien Gallop
MCIS mass scan
I have begun a mass scan from 0 to 25.
It will be a while. Data file: masscorr_mcis__0-25_090714.txt.
25nA of 18O4+ restored to FC6.
72
Wed Jul 15 09:20:26 2009
Damien Gallop
Supernanogan development in progress
Proposed run plan for this time:
Document TIGRESS tune.
18O4+ emittance scan.
Mass
73
Wed Jul 15 10:27:18 2009
Damien Gallop
18O4+ overnight and emittance check
Repeat emittance scan of present 18O4+
beam. It compares okay (somewhat broader
emittance numbers) with yesterday's
74
Wed Jul 15 10:41:23 2009
Damien Gallop
18O8+ survey
A/q = 2.25 Field = 704.7G FC6 = <pA
Well, it's there, but pretty faint.
The attached stripchart shows no beam then
75
Wed Jul 15 10:51:25 2009
Damien Gallop
18O7+ survey
A/q = 2.571 Field = 752.9 FC6 = 88pA
76
Wed Jul 15 10:52:25 2009
Damien Gallop
18O6+ survey
A/q = 3 Field = 813.2 FC6 = 2.9nA
Beam is too faint for a good emittance
scan, but it's visible. Redo with reverse
7x
77
Wed Jul 15 14:41:25 2009
Damien Gallop
18O5+ survey
A/q = 3.6 Field = 888.6G FC6 = 10nA
Two emittance scans, one with the
as-is emittance rig, one with a manually
78
Wed Jul 15 16:37:01 2009
Damien Gallop
Bias for IOS emittance rig
Graham looked up the list of IOS bias assignments.
None was form the emittance rig. I quickly
tested the list in ILT, but nothing jumped
79
Thu Jul 16 14:06:56 2009
Damien Gallop
MCIS vacuum trip overnight
The MCIS vacuum system tripped last night
again. Fortunately the operators
noticed it and restarted stuff. Otherwise
80
Thu Jul 16 14:11:43 2009
Damien Gallop
MCOL3 slits calibrations
I ran through a calibration exercise for
the IOS slits. Here is my data. I have moved
each set to the midpoint of the largest (5mm)
81
Thu Jul 16 14:25:27 2009
Damien Gallop
18O4+ survey
A/q = 4.5 Field = 993.5G FC6 = 24.0enA
82
Thu Jul 16 14:41:46 2009
Damien Gallop
16O8+ survey
A/q = 2 Field = 662.3G FC6 = 150epA (unstable)
No emittance scan possible.
83
Thu Jul 16 14:44:06 2009
Damien Gallop
18O8+ survey
A/q = 2.25 Field = 702.5G FC6 = not visible
It looks like last night's vacuum
trip is biting us here.
Goto page
Previous
1
,
2
,
3
...
5
, 6,
7
...
24
,
25
,
26
Next
ELOG V2.9.2-2455