|   | 
ID | 
Date | 
Author | 
Type | 
Category | 
Subject | 
Text | 
  | 
| 
 | 
  453  
 | 
Wed Oct 19 09:53:27 2011 | 
Damien Gallop |   |   | 33S from MCIS to HE Development Setup | MCIS configured for 33S+6 yesterday afternoon. 
Beam grew nicely overnight. Beam development 
expected after source hand-off. | 
    | 
| 
 | 
  452  
 | 
Tue Oct 18 10:27:44 2011 | 
Damien Gallop |   |   | 19F/38Ar from MCIS for Beam Development | Cocktail beams continue today. | 
    | 
| 
 | 
  451  
 | 
Mon Oct 17 11:33:03 2011 | 
Damien Gallop |   |   | 19F/38Ar from MCIS for Beam Development | Source set up for a cocktail beam since 
yesterday, Sunday. | 
   | 
| 
 | 
  450  
 | 
Thu Oct 13 11:11:14 2011 | 
Damien Gallop |   |   | 14N+2 from MWS to SEBT for Beam Development | Source setup took place earlier this morning. | 
    | 
| 
 | 
  449  
 | 
Thu Oct  6 15:15:09 2011 | 
Damien Gallop |   |   | 19F/40Ar from MCIS for Beam Development | Slit calibration exercise was wound up 
this morning. MCIS source gases were reconfigured 
with 19F and 40Ar by request. A "cocktail" | 
    | 
| 
 | 
  448  
 | 
Wed Oct  5 10:11:28 2011 | 
Damien Gallop |   |   | 33S from MCIS Source Development | The source stayed up overnight. A little 
RF tweak, but 33S+6 beam still on FC6.
 
Later... IOS:MCOL3 slits calibration | 
    | 
| 
 | 
  447  
 | 
Tue Oct  4 10:37:38 2011 | 
Damien Gallop |   |   | 33S from MCIS Source Development Setup | Beam development with 116Sn+18 finished 
last evening around 21:00. Source was off 
overnight. 33S material loaded into MCIS | 
     | 
| 
 | 
  446  
 | 
Mon Oct  3 10:08:50 2011 | 
Damien Gallop |   |   | 116Sn+18 & 118Sn+19 from MCIS for Development | On Friday there was a request to repeat 
some of the findings with tin beams. An agreement 
was made to use OLIS for development in lieu | 
     | 
| 
 | 
  445  
 | 
Thu Sep 29 10:50:30 2011 | 
Damien Gallop |   |   | 36/40Ar development with MCIS | Development with Supernanogan source continues. 
Present beam is 40Ar+7, about 70enA. | 
   | 
| 
 | 
  444  
 | 
Wed Sep 28 11:56:15 2011 | 
Damien Gallop |   |   | 36/40Ar development with MCIS | 40Ar source gas, ergo 40Ar+x beams. 40Ar+6 
earlier, and 40Ar+7 presently. | 
    | 
| 
 | 
  443  
 | 
Tue Sep 27 13:29:23 2011 | 
Damien Gallop |   |   | 36/40Ar development with MCIS | Beam development for forthcoming 36Ar run 
is in progress. Initial yield numbers have 
been determined. Source is running with Ar | 
   | 
| 
 | 
  442  
 | 
Mon Sep 26 09:47:12 2011 | 
Damien Gallop |   |   | 13C+3 from MCIS to TACTIC | The 17O+3 (A/q=5.66) run to TACTIC finished 
yesterday morning. Then a source switchover 
was done to deliver 13C+3 (A/q=4.33) using | 
     | 
| 
 | 
  441  
 | 
Fri Sep 23 14:59:14 2011 | 
Damien Gallop |   |   | 14N+3 & 17O+3 from MCIS to TACTIC at HEBT | Delivery continues. 14N+3 until mid-morning, 
then a switch to 17O+3 for tuning. The switchover 
from 116Sn to TIGRESS to 14N+3 to TACTIC | 
      | 
| 
 | 
  440  
 | 
Mon Sep 19 10:27:36 2011 | 
Damien Gallop |   |   | 116Sn+18 & 118Sn+19 from MCIS to TIGRESS | Delivery continued over the weekend with 
some interruptions here and there. A source 
intervention was made late last night and | 
    | 
| 
 | 
  439  
 | 
Fri Sep 16 10:02:33 2011 | 
Damien Gallop |   |   | 116Sn+18 & 118Sn+19 from MCIS to TIGRESS | Beam was changed to 14N+2 last evening 
for sake of tuning to front of RFQ. Source 
was tweaked earlier. Beam is presently set | 
    | 
| 
 | 
  438  
 | 
Thu Sep 15 12:09:25 2011 | 
Damien Gallop |   |   | 116Sn+18 & 118Sn+19 from MCIS to TIGRESS Setup | Source switchover began last night after 
22:00. There are some 200epA of A/q=6.46 
(116Sn+18) on FC6 presently. Setup and tuning | 
      | 
| 
 | 
  437  
 | 
Thu Sep 15 11:29:39 2011 | 
Damien Gallop |   |   | 12C+2 from MCIS to DRAGON EOB | Beam delivery was scheduled to end last 
evening at 20:30. It was extended to around 
22:00, at which point source switchover began. | 
    | 
| 
 | 
  436  
 | 
Wed Sep 14 10:00:05 2011 | 
Damien Gallop |   |   | 12C+2 from MCIS to DRAGON | Delivery continues. Nice consistency. See 
attached Stripchart. A source switchover 
is scheduled for today, tonight, as it turns | 
    | 
| 
 | 
  435  
 | 
Tue Sep 13 10:00:56 2011 | 
Damien Gallop |   |   | 12C+2 from MCIS to DRAGON | Delivery continued through the night. User 
was taking the beam. Recovery from a DTL 
tank trip is happening at the moment. Otherwise, | 
    | 
| 
 | 
  434  
 | 
Mon Sep 12 10:07:36 2011 | 
Damien Gallop |   |   | 12C+2 from MCIS to DRAGON Setup | Setup began around 09:00. 400enA of A/q=6 
on FC6 presently.
 
Later... By ~14:00 beam looks pretty | 
     |