55
|
Wed Jul 8 18:12:25 2009 |
Damien Gallop | Routine | General | 18O2+ emittance scan |
A/q = 9 FC6 = 50.0nA MB = 1470.8G @ 90.8A |
Attachment 1: grab.LL3034.png
|
|
Attachment 2: grab.Yj3038.png
|
|
56
|
Wed Jul 8 18:20:43 2009 |
Damien Gallop | Routine | General | 18O3+ emittance scan |
A/q = 6 FC6 = 49.5nA MB = 1201.4G @ 73.1A |
Attachment 1: grab.Pc3095.png
|
|
Attachment 2: grab.Oi3099.png
|
|
57
|
Wed Jul 8 18:38:21 2009 |
Damien Gallop | Routine | General | 18O4+ emittance scan |
A/q = 4.5 FC6 = 29.5nA MB = 1041.8G @ 62.4A |
Attachment 1: grab.Cb3157.png
|
|
Attachment 2: grab.wO3161.png
|
|
58
|
Wed Jul 8 18:47:43 2009 |
Damien Gallop | Routine | General | 18O5+ emittance scan |
A/q = 3.6 FC6 = 12.5nA MB = 931.8G @ 55.3A |
Attachment 1: grab.IW3188.png
|
|
Attachment 2: grab.kW3192.png
|
|
59
|
Wed Jul 8 18:57:09 2009 |
Damien Gallop | Routine | General | 18O6+ emittance scan |
A/q = 3 FC6 = 5.5nA MB = 851.5G @ 50.1A |
Attachment 1: grab.cb3228.png
|
|
Attachment 2: grab.un3232.png
|
|
60
|
Wed Jul 8 19:07:15 2009 |
Damien Gallop | Routine | General | 18O7+ emittance scan |
A/q = 2.57 FC6 = 0.25nA MB = 790.0G @ 46.2A
Not enough intensity for an emittance scan. |
Attachment 1: grab.ca3306.png
|
|
61
|
Wed Jul 8 19:13:15 2009 |
Damien Gallop | Routine | General | 18O8+ emittance scan |
A/q = 2.25 FC6 at reverse bias MB = 736.9G @ 42.9A
Not enough intensity for an emittance scan. Possibly on the edge of A/q=2.3 (23Na10+?). |
Attachment 1: grab.Ah3293.png
|
|
Attachment 2: grab.ed3302.png
|
|
Attachment 3: grab.Nc3298.png
|
|
62
|
Wed Jul 8 19:51:33 2009 |
Damien Gallop | Routine | General | 18On+ summary for the day |
The 18O source gas bottle is online. The ion source was optimized for 18O4+ and kept the same throughout. Emittance scans of each charge state of 18O were attempted. Visible scans were found for all states up to 6+. At least one more set of scans is desireable. Present beam is 18O4+. Next up: RF frequency survey with 18On+. |
Attachment 1: grab.TF3397.png
|
|
Attachment 2: grab.fu3402.png
|
|
Attachment 3: grab.Tk3406.png
|
|
63
|
Thu Jul 9 16:07:56 2009 |
Damien Gallop | Routine | General | 18O8+ frequency scans |
Keerthi did some 18On+ frequency scans this morning. He observed 18O8+! I am attempting to repeat it myself now. Reverse bias on FC6.
Peaks at:
13.0277GHz => 1epA (unstable)
13.1023GHz => 1epA (unstable)
13.1695GHz => 10epA (unstable)
13.1672GHz => 20epA (unstable) stripchart attached
13.006GHz => .7epA stripchart at 17:24 attached
First, optimize current versus frequency and amplitude. Unfortunately at 5dB the beam blinked out. Go fishing, then find it again. Attached is stripchart at 17:30, where I was optimizing, then switched bias to Normal, then watched beam blink out. Then stripchart at 17:49 shows beam back again, reverse bias on the left and normal bias on the right: ~10epA. RF settings also attached. Minutes later, beam is still on. FTR, the original RF is appended at the end.
|
Attachment 1: grab.hM6579.png
|
|
Attachment 2: grab.OC6749.png
|
|
Attachment 3: grab.pj6791.png
|
|
Attachment 4: grab.Zw6832.png
|
|
Attachment 5: grab.ko6836.png
|
|
Attachment 6: grab.xu6426.png
|
|
64
|
Fri Jul 10 09:55:25 2009 |
Damien Gallop | Routine | General | 18O8+ beam overnight |
Here is a striptool of 18O8+ beam (magenta trace) last evening from about 18:00 to 22:30 when there was a large power bump coincident with a plane crash in Richmond last night. Before the trip, beam current was about 20epA on FC6 (normal bias). |
Attachment 1: grab.N10241.png
|
|
65
|
Fri Jul 10 11:46:55 2009 |
Damien Gallop | Routine | General | 18On+ frequency scans & resonances |
The Supernanogan was restarted this morning, after last night's power bump. 18O4+ on FC6, cooking for about an hour. Looks very good. Keerthi is doing frequency scans today to find best resonances. Time permitting, he will do this over a range of 18O charge states. At some point over the weekend (my guess is tomorrow evening), he will open the 17O source gas bottle to the system. |
Attachment 1: Picture_18.png
|
|
66
|
Fri Jul 10 11:47:07 2009 |
Damien Gallop | Routine | General | 18On+ frequency scans & resonances |
The Supernanogan was restarted this morning, after last night's power bump. 18O4+ on FC6, cooking for about an hour. Looks very good. Keerthi is doing frequency scans today to find best resonances. Time permitting, he will do this over a range of 18O charge states. He is also developing a dual-mode (MCIS/MWS) IOS tune. At some point over the weekend (my guess is tomorrow evening), he will open the 17O source gas bottle to the system. |
Attachment 1: Picture_18.png
|
|
138
|
Tue Sep 15 19:46:21 2009 |
Keerthi | Routine | General | Supernanogan emittance scans |
090915_1915ILTEMIT.txt = 17O +3, 4.4uA new tune, scanner offset +10V, scanner scale 100nA , 100x50 matrix
090915_1929ILTEMIT.txt = same as above with 200x100 matrix
090915_1949ILTEMIT.txt = after tune tweaking (not optimal; for reference only) |
Attachment 1: grab.w23925.png
|
|
Attachment 2: grab.L23930.png
|
|
Attachment 3: grab.J23942.png
|
|
Attachment 4: grab.K23948.png
|
|
Attachment 5: grab.N23902.png
|
|
Attachment 6: grab.f23908.png
|
|
Attachment 7: grab.C23914.png
|
|
Attachment 8: grab.v23919.png
|
|
Attachment 9: grab.y24035.png
|
|
140
|
Wed Sep 16 12:12:04 2009 |
Keerthi | Routine | General | 17O+3 emittance sacns |
090916_1156ILTEMIT.txt 17O+3 good settings 50x100 , 333nA Scale, ~4uA
090916_1206ILTEMIT.txt 17O+3 good settings 100x200 , 333nA Scale, ~4uA |
142
|
Wed Sep 16 12:26:51 2009 |
Keerthi | Routine | General | 17O+3 emittance with changed steering |
090916_1222ILTEMIT.txt Changed the MCIS steering to center the beam in the EL. 17O+3 ~5uA, 50x100 |
148
|
Fri Oct 2 09:38:26 2009 |
Keerthi | Routine | General | 33Sulfur development completed successfully. |
Sulfur-33 development completed successfully.
Three times of the requested amount produced (1e9 x 3) from the source and two times
delivered to the DRAGON for verification.
The SO2 gas bottle is removed and stored in the ISAC gas shack. |
264
|
Fri May 7 19:10:05 2010 |
Keerthi Jayamanna | Routine | General | OLIS status |
MW source is back and running.
A new vacuum chamber is added to the Supernanogan RF block.
SO2 is not filled in yet. |
469
|
Sun Dec 2 22:32:19 2012 |
Keerthi Jayamanna | Routine | General | Still cannot write anything other than Subject |
|
471
|
Sun Dec 2 23:36:13 2012 |
Keerthi Jayamanna | Routine | General | 16O+2 is ready for tuning. |
MCIS finished xenon development. MCIS is off and isolation valve is shut.
A new oxygen gas line is installed to microwave ion source via a hand valve neat PE.
Hand valve is tuned as a small leak so that the plasma can run with all other gas valves are shut.
However if one need to start the source Ne gas valves are needed to be opened.
A 3.13nA of 16O+2 is sitting at FC6 and ready to use as pilot beam. |
479
|
Fri May 16 08:44:27 2014 |
Raymond Dubé | Routine | General | OLIS work next week |
Attached is the scheduled work for OLIS next week. |
Attachment 1: OLIS-Work-05.pdf
|