OLIS Logbook General
  General, Page 24 of 26  Not logged in ELOG logo
Entry  Wed Sep 7 09:50:20 2011, Damien Gallop, , , 58Ni1+ from MWS to TITAN Picture_52.png

Delivery continues. Source change scheduled for 20:30 this evening.

Entry  Thu Sep 8 11:21:45 2011, Damien Gallop, , , 4He from MCIS to DRAGON Setup Picture_53.png

The 58Ni delivery from MWS to TITAN ended last evening. Beam was unused from about 18:30, and source switchover began at about 22:00. A 4He1+ beam from MCIS was established by 03:00 this morning. Around 35pA is available on FC6 presently. Note that at A/q=4, there are likely contributions from 12C+3 and 16O+4.

Entry  Mon Sep 12 10:04:42 2011, Damien Gallop, , , 4He from MCIS to DRAGON EOB Picture_1.pngPicture_2.png

Delivery continued through the weekend. Some 300nA on FC6. The run ended at around 09:00. Source switchover is in progress now.

Entry  Mon Sep 12 10:07:36 2011, Damien Gallop, , , 12C+2 from MCIS to DRAGON Setup Picture_3.pngPicture_4.png

Setup began around 09:00. 400enA of A/q=6 on FC6 presently.

Later... By ~14:00 beam looks pretty good. See Stripchart below.

Entry  Tue Sep 13 10:00:56 2011, Damien Gallop, , , 12C+2 from MCIS to DRAGON Picture_1.png

Delivery continued through the night. User was taking the beam. Recovery from a DTL tank trip is happening at the moment. Otherwise, beam is very good. And strong.

Entry  Wed Sep 14 10:00:05 2011, Damien Gallop, , , 12C+2 from MCIS to DRAGON Picture_2.png

Delivery continues. Nice consistency. See attached Stripchart. A source switchover is scheduled for today, tonight, as it turns out. Good luck with that.

Entry  Thu Sep 15 11:29:39 2011, Damien Gallop, , , 12C+2 from MCIS to DRAGON EOB Picture_5.png

Beam delivery was scheduled to end last evening at 20:30. It was extended to around 22:00, at which point source switchover began.

Entry  Thu Sep 15 12:09:25 2011, Damien Gallop, , , 116Sn+18 & 118Sn+19 from MCIS to TIGRESS Setup Picture_6.pngPicture_7.pngPicture_10.png

Source switchover began last night after 22:00. There are some 200epA of A/q=6.46 (116Sn+18) on FC6 presently. Setup and tuning continue.

Natural abundances of Sn:

Sn-116 ( 14.54% )
Sn-117 ( 7.68% )
Sn-118 ( 24.22% )
Sn-119 ( 8.58% )
Sn-120 ( 32.59% )
Sn-122 ( 4.63% )
Sn-124 ( 5.79% )

Later... ~70epA at FC6 after some conditioning and fiddling.

Entry  Fri Sep 16 10:02:33 2011, Damien Gallop, , , 116Sn+18 & 118Sn+19 from MCIS to TIGRESS Picture_12.png

Beam was changed to 14N+2 last evening for sake of tuning to front of RFQ. Source was tweaked earlier. Beam is presently set to 116Sn+18 with tuning activities in progress.

Entry  Mon Sep 19 10:27:36 2011, Damien Gallop, , , 116Sn+18 & 118Sn+19 from MCIS to TIGRESS Picture_15.png

Delivery continued over the weekend with some interruptions here and there. A source intervention was made late last night and into the wee hours, and again this morning. Tuning to TIGRESS has resumed.

Note that ICR was using a 12C+2 beam for setup purposes. Their procedure was to turn off MCIS when beam not in use to minimize carbon contamination in the source. 12C+2 -> 116Sn+18 last evening around 21:00 with source expert present.

Entry  Fri Sep 23 14:59:14 2011, Damien Gallop, , , 14N+3 & 17O+3 from MCIS to TACTIC at HEBT Picture_16.pngPicture_17.pngPicture_18.png

Delivery continues. 14N+3 until mid-morning, then a switch to 17O+3 for tuning. The switchover from 116Sn to TIGRESS to 14N+3 to TACTIC was done on Tuesday mid-morning.

Entry  Mon Sep 26 09:47:12 2011, Damien Gallop, , , 13C+3 from MCIS to TACTIC Picture_20.pngPicture_19.png

The 17O+3 (A/q=5.66) run to TACTIC finished yesterday morning. Then a source switchover was done to deliver 13C+3 (A/q=4.33) using enriched 13CO2 source gas.

Later... TACTIC is done. Next up: beam development at MCIS for upcoming 36Ar run.

Entry  Tue Sep 27 13:29:23 2011, Damien Gallop, , , 36/40Ar development with MCIS 

Beam development for forthcoming 36Ar run is in progress. Initial yield numbers have been determined. Source is running with Ar plasma presently, and tests will be repeated after source has conditioned for a while. The goal is to determine yield numbers of 40Ar and scale these to beam to be produced with source gas of enriched 36Ar. FYI:

Naturally occuring isotopes of argon:

Ar-36 ( 0.3365% )
Ar-38 ( 0.0632% )
Ar-40 ( 99.6003% )

Entry  Wed Sep 28 11:56:15 2011, Damien Gallop, , , 36/40Ar development with MCIS Picture_21.png

40Ar source gas, ergo 40Ar+x beams. 40Ar+6 earlier, and 40Ar+7 presently.

Entry  Thu Sep 29 10:50:30 2011, Damien Gallop, , , 36/40Ar development with MCIS 

Development with Supernanogan source continues. Present beam is 40Ar+7, about 70enA.

Entry  Mon Oct 3 10:08:50 2011, Damien Gallop, , , 116Sn+18 & 118Sn+19 from MCIS for Development Picture_22.pngPicture_23.png

On Friday there was a request to repeat some of the findings with tin beams. An agreement was made to use OLIS for development in lieu of Shutdown MRO as scheduled. MRO is planned for November 2nd &ff. HE development took place over the weekend with 116Sn+18, A/q=6.44.

Next up: 33S source development. Setup this evening.

Entry  Tue Oct 4 10:37:38 2011, Damien Gallop, , , 33S from MCIS Source Development Setup Picture_24.pngPicture_25.png

Beam development with 116Sn+18 finished last evening around 21:00. Source was off overnight. 33S material loaded into MCIS oven. Source pumped overnight.

Later... source is lit. 33S+6 on FC6 and growing.

Entry  Wed Oct 5 10:11:28 2011, Damien Gallop, , , 33S from MCIS Source Development Picture_1.png

The source stayed up overnight. A little RF tweak, but 33S+6 beam still on FC6.

Later... IOS:MCOL3 slits calibration with beam in progress.

Entry  Thu Oct 6 15:15:09 2011, Damien Gallop, , , 19F/40Ar from MCIS for Beam Development Picture_4.png

Slit calibration exercise was wound up this morning. MCIS source gases were reconfigured with 19F and 40Ar by request. A "cocktail" beam will be used for HE development over the Thanksgiving weekend. A mass scan is in progress presently.

Entry  Thu Oct 13 11:11:14 2011, Damien Gallop, , , 14N+2 from MWS to SEBT for Beam Development Picture_5.png

Source setup took place earlier this morning.

ELOG V2.9.2-2455