OLIS Logbook General
  General, Page 23 of 26  Not logged in ELOG logo
IDdown Date Author Type Category Subject Text Attachments
  73   Wed Jul 15 10:27:18 2009 Damien Gallop  18O4+ overnight and emittance checkRepeat emittance scan of present 18O4+
beam. It compares okay (somewhat broader
emittance numbers)  with yesterday's
 grab.tL7839.pnggrab.An7844.pnggrab.fH7848.pnggrab.Jq7854.png 
  72   Wed Jul 15 09:20:26 2009 Damien Gallop  Supernanogan development in progressProposed run plan for this time:

    Document TIGRESS tune.

   18O4+ emittance scan.
    Mass
  
  71   Tue Jul 14 15:19:51 2009 Damien Gallop  MCIS mass scanI have begun a mass scan from 0 to 25.
It will be a while. Data file: masscorr_mcis__0-25_090714.txt.
25nA of 18O4+ restored to FC6.
 grab.qQ4911.png 
  70   Tue Jul 14 09:47:14 2009 Damien Gallop  18O4+ tuning to TIGRESS this morningWe have a change of schedule. Due to circumstances,
Sophia will continue tuning to TIGRESS this
morning. Sgan Development will resume this
 7x 
  69   Mon Jul 13 17:41:04 2009 Damien Gallop  Supernanogan development Monday morningAs noted, Keerthi was called to restart
the source after a power bump. He continued
Supernanogan development through the night
 Picture_20.png 
  68   Mon Jul 13 17:19:29 2009 Damien Gallop  MCIS vacuum trip at ~15:30An MCIS vacuum trip occurred somewhere
around 15:30. Sophia observed a drop-off
in beam. The cause looks like the PLC-related
 grab.Z26697.png 
  67   Mon Jul 13 09:49:52 2009 Damien Gallop  18O4+ tuning to TIGRESS todayAs per our agreed deal last week, today
is reserved for Supernanogan tuning to TIGRESS.
Development will resume tomorrow.
 Picture_19.png 
  66   Fri Jul 10 11:47:07 2009 Damien GallopRoutineGeneral18On+ frequency scans & resonancesThe Supernanogan was restarted this morning,
after last night's power bump. 18O4+ on FC6,
cooking for about an hour. Looks very good.
 Picture_18.png 
  65   Fri Jul 10 11:46:55 2009 Damien GallopRoutineGeneral18On+ frequency scans & resonancesThe Supernanogan was restarted this morning,
after last night's power bump. 18O4+ on FC6,
cooking for about an hour. Looks very good.
 Picture_18.png 
  64   Fri Jul 10 09:55:25 2009 Damien GallopRoutineGeneral18O8+ beam overnightHere is a striptool of 18O8+ beam (magenta
trace) last evening from about 18:00 to 22:30
when there was a large power bump coincident
 grab.N10241.png 
  63   Thu Jul 9 16:07:56 2009 Damien GallopRoutineGeneral18O8+ frequency scansKeerthi did some 18On+ frequency scans
this morning. He observed 18O8+! I am attempting
to repeat it myself now. Reverse bias on
 6x 
  62   Wed Jul 8 19:51:33 2009 Damien GallopRoutineGeneral18On+ summary for the dayThe 18O source gas bottle is online. The
ion source was optimized for 18O4+ and kept
the same throughout. Emittance scans of each
 grab.TF3397.pnggrab.fu3402.pnggrab.Tk3406.png 
  61   Wed Jul 8 19:13:15 2009 Damien GallopRoutineGeneral18O8+ emittance scanA/q = 2.25 FC6 at reverse bias MB = 736.9G
@ 42.9A
Not enough intensity for an emittance
 grab.Ah3293.pnggrab.ed3302.pnggrab.Nc3298.png 
  60   Wed Jul 8 19:07:15 2009 Damien GallopRoutineGeneral18O7+ emittance scanA/q = 2.57 FC6 = 0.25nA MB = 790.0G @ 46.2A
Not enough intensity for an emittance
scan.
 grab.ca3306.png 
  59   Wed Jul 8 18:57:09 2009 Damien GallopRoutineGeneral18O6+ emittance scanA/q = 3 FC6 = 5.5nA MB = 851.5G @ 50.1A  grab.cb3228.pnggrab.un3232.png 
  58   Wed Jul 8 18:47:43 2009 Damien GallopRoutineGeneral18O5+ emittance scanA/q = 3.6 FC6 = 12.5nA MB = 931.8G @ 55.3A  grab.IW3188.pnggrab.kW3192.png 
  57   Wed Jul 8 18:38:21 2009 Damien GallopRoutineGeneral18O4+ emittance scanA/q = 4.5 FC6 = 29.5nA MB = 1041.8G @ 62.4A  grab.Cb3157.pnggrab.wO3161.png 
  56   Wed Jul 8 18:20:43 2009 Damien GallopRoutineGeneral18O3+ emittance scanA/q = 6 FC6 = 49.5nA MB = 1201.4G @ 73.1A  grab.Pc3095.pnggrab.Oi3099.png 
  55   Wed Jul 8 18:12:25 2009 Damien GallopRoutineGeneral18O2+ emittance scanA/q = 9 FC6 = 50.0nA MB = 1470.8G @ 90.8A  grab.LL3034.pnggrab.Yj3038.png 
  54   Wed Jul 8 17:58:02 2009 Damien GallopRoutineGeneral18O1+ emittance scanHere we go. A/q = 18 FC6 = 141.0nA MB =
2078G @ 130.2A
 grab.QR2996.pnggrab.dm3000.png 
ELOG V2.9.2-2455