OLIS Logbook General
  General, Page 23 of 26  Not logged in ELOG logo
Entry  Wed Jul 15 10:27:18 2009, Damien Gallop, , , 18O4+ overnight and emittance check grab.tL7839.pnggrab.An7844.pnggrab.fH7848.pnggrab.Jq7854.png
Repeat emittance scan of present 18O4+ beam. It compares okay (somewhat broader emittance numbers)  with yesterday's scan. Also attached is FC6
beam overnight. Nice.
Entry  Wed Jul 15 09:20:26 2009, Damien Gallop, , , Supernanogan development in progress 
Proposed run plan for this time:

    Document TIGRESS tune.
    18O4+ emittance scan.
    Mass scan A/q = 0 to 25.
    Repeat 18On+ emittance
scans at present RF frequency. 
    16On+ emittance scans at present frequency.
    Plot 16On+ & 18On+ emittance on one graph.
Entry  Tue Jul 14 15:19:51 2009, Damien Gallop, , , MCIS mass scan grab.qQ4911.png
I have begun a mass scan from 0 to 25. It will be a while. Data file: masscorr_mcis__0-25_090714.txt.
25nA of 18O4+ restored to FC6.
Entry  Tue Jul 14 09:47:14 2009, Damien Gallop, , , 18O4+ tuning to TIGRESS this morning 7x
We have a change of schedule. Due to circumstances, Sophia will continue tuning to TIGRESS this morning. Sgan Development will resume this afternoon.
Details: The beam path through the TIGRESS chamber is clear presently, and no detectors are mounted. It is the perfect time to send a nA pilot
beam to the end of the line. TIGRESS intends to install electronics starting at noon. Sophia expects to have tuning comfortably completed by then also.
Entry  Mon Jul 13 17:41:04 2009, Damien Gallop, , , Supernanogan development Monday morning Picture_20.png
As noted, Keerthi was called to restart the source after a power bump. He continued Supernanogan development through the night (can you imagine?!?).
He made some great progress. Here is a partial summary of his findings.
Actions taken: frequency scans across the entire range from 12-16GHz for each charge state of 18O.
Entry  Mon Jul 13 17:19:29 2009, Damien Gallop, , , MCIS vacuum trip at ~15:30 grab.Z26697.png
An MCIS vacuum trip occurred somewhere around 15:30. Sophia observed a drop-off in beam. The cause looks like the PLC-related business that we have experienced
many times before. This fault has not manifested itself for quite a while, since Controls firewalled the MCIS portion of the network on March 30th.
Entry  Mon Jul 13 09:49:52 2009, Damien Gallop, , , 18O4+ tuning to TIGRESS today Picture_19.png
As per our agreed deal last week, today is reserved for Supernanogan tuning to TIGRESS. Development will resume tomorrow.
There was a power bump overnight that knocked out many systems, including OLIS. The ISAC elog mentions something about it here.
It seems that Keerthi restarted the source. (Note to self: Write an ION with brief restart instructions for the Supernanogan.) 18O4+ beam was left on FC6,
Entry  Fri Jul 10 11:47:07 2009, Damien Gallop, Routine, General, 18On+ frequency scans & resonances Picture_18.png
The Supernanogan was restarted this morning, after last night's power bump. 18O4+ on FC6, cooking for about an hour. Looks very good. Keerthi is doing
frequency scans today to find best resonances. Time permitting, he will do this over a range of 18O charge states. He is also developing a dual-mode (MCIS/MWS)
IOS tune. At some point over the weekend (my guess is tomorrow evening), he will open the 17O source gas bottle to the system.
Entry  Fri Jul 10 11:46:55 2009, Damien Gallop, Routine, General, 18On+ frequency scans & resonances Picture_18.png
The Supernanogan was restarted this morning, after last night's power bump. 18O4+ on FC6, cooking for about an hour. Looks very good. Keerthi is doing
frequency scans today to find best resonances. Time permitting, he will do this over a range of 18O charge states. At some point over the weekend (my guess
is tomorrow evening), he will open the 17O source gas bottle to the system.
Entry  Fri Jul 10 09:55:25 2009, Damien Gallop, Routine, General, 18O8+ beam overnight grab.N10241.png
Here is a striptool of 18O8+ beam (magenta trace) last evening from about 18:00 to 22:30 when there was a large power bump coincident with a plane
crash in Richmond last night. Before the trip, beam current was about 20epA on FC6 (normal bias).
Entry  Thu Jul 9 16:07:56 2009, Damien Gallop, Routine, General, 18O8+ frequency scans 6x
Keerthi did some 18On+ frequency scans this morning. He observed 18O8+! I am attempting to repeat it myself now. Reverse bias on FC6.
Peaks at:
13.0277GHz => 1epA (unstable)
Entry  Wed Jul 8 19:51:33 2009, Damien Gallop, Routine, General, 18On+ summary for the day grab.TF3397.pnggrab.fu3402.pnggrab.Tk3406.png
The 18O source gas bottle is online. The ion source was optimized for 18O4+ and kept the same throughout. Emittance scans of each charge state of 18O
were attempted. Visible scans were found for all states up to 6+. At least one more set of scans is desireable. Present beam is 18O4+. Next up: RF frequency
survey with 18On+.
Entry  Wed Jul 8 19:13:15 2009, Damien Gallop, Routine, General, 18O8+ emittance scan grab.Ah3293.pnggrab.ed3302.pnggrab.Nc3298.png
A/q = 2.25 FC6 at reverse bias MB = 736.9G @ 42.9A
Not enough intensity for an emittance scan. Possibly on the edge of A/q=2.3 (23Na10+?).
Entry  Wed Jul 8 19:07:15 2009, Damien Gallop, Routine, General, 18O7+ emittance scan grab.ca3306.png
A/q = 2.57 FC6 = 0.25nA MB = 790.0G @ 46.2A
Not enough intensity for an emittance scan.
Entry  Wed Jul 8 18:57:09 2009, Damien Gallop, Routine, General, 18O6+ emittance scan grab.cb3228.pnggrab.un3232.png
A/q = 3 FC6 = 5.5nA MB = 851.5G @ 50.1A
Entry  Wed Jul 8 18:47:43 2009, Damien Gallop, Routine, General, 18O5+ emittance scan grab.IW3188.pnggrab.kW3192.png
A/q = 3.6 FC6 = 12.5nA MB = 931.8G @ 55.3A
Entry  Wed Jul 8 18:38:21 2009, Damien Gallop, Routine, General, 18O4+ emittance scan grab.Cb3157.pnggrab.wO3161.png
A/q = 4.5 FC6 = 29.5nA MB = 1041.8G @ 62.4A
Entry  Wed Jul 8 18:20:43 2009, Damien Gallop, Routine, General, 18O3+ emittance scan grab.Pc3095.pnggrab.Oi3099.png
A/q = 6 FC6 = 49.5nA MB = 1201.4G @ 73.1A
Entry  Wed Jul 8 18:12:25 2009, Damien Gallop, Routine, General, 18O2+ emittance scan grab.LL3034.pnggrab.Yj3038.png
A/q = 9 FC6 = 50.0nA MB = 1470.8G @ 90.8A
Entry  Wed Jul 8 17:58:02 2009, Damien Gallop, Routine, General, 18O1+ emittance scan grab.QR2996.pnggrab.dm3000.png
Here we go. A/q = 18 FC6 = 141.0nA MB = 2078G @ 130.2A
ELOG V2.9.2-2455