OLIS Logbook
General
General, Page 22 of 26
Not logged in
List
|
Find
|
Select
|
Import
|
Login
|
Help
New entries since:
Wed Dec 31 16:00:00 1969
Full
| Summary |
Threaded
513 Entries
Goto page
Previous
1
,
2
,
3
...
21
, 22,
23
,
24
,
25
,
26
Next
ID
Date
Author
Type
Category
Subject
Text
93
Thu Jul 16 16:33:28 2009
Damien Gallop
18O3+ survey
A/q = 6 Field = 1147.2 FC6 = 39.3enA
92
Thu Jul 16 16:15:39 2009
Damien Gallop
16O3+ survey
A/q = 5.3333 Field = 1081.6G FC6 = 110nA
91
Thu Jul 16 15:58:53 2009
Damien Gallop
18O4+ survey
A/q = 4.5 Field = 993.5G FC6 = 20enA
90
Thu Jul 16 15:49:46 2009
Damien Gallop
16O4+ survey
A/q = 4 Field = 936.7 FC6 = 54.0enA
89
Thu Jul 16 15:41:35 2009
Damien Gallop
18O5+ survey
A/q = 3.6 Field = 888.6G FC6 = 6.2enA
88
Thu Jul 16 15:38:58 2009
Damien Gallop
16O5+ survey
A/q = 3.2 Field = 837.7G FC6 = 14.5enA
87
Thu Jul 16 15:22:51 2009
Damien Gallop
18O6+ survey
A/q = 3 Field = 811.2G FC6 = 1.6nA
Not quite enough beam for an emittance
scan.
86
Thu Jul 16 15:11:16 2009
Damien Gallop
16O6+ survey
A/q = 2.6667 Field = 764.7G FC6 = 3.0nA
85
Thu Jul 16 14:50:38 2009
Damien Gallop
18O7+ survey
A/q = 2.5714 Field = 751.1G FC6 = 40epA
No emittance scan possible.
84
Thu Jul 16 14:46:52 2009
Damien Gallop
16O7+ survey
A/q = 2.2857 Field = 708.0G FC6 = 70epA
(noisy)
No emittance scan possible.
83
Thu Jul 16 14:44:06 2009
Damien Gallop
18O8+ survey
A/q = 2.25 Field = 702.5G FC6 = not visible
It looks like last night's vacuum
trip is biting us here.
82
Thu Jul 16 14:41:46 2009
Damien Gallop
16O8+ survey
A/q = 2 Field = 662.3G FC6 = 150epA (unstable)
No emittance scan possible.
81
Thu Jul 16 14:25:27 2009
Damien Gallop
18O4+ survey
A/q = 4.5 Field = 993.5G FC6 = 24.0enA
80
Thu Jul 16 14:11:43 2009
Damien Gallop
MCOL3 slits calibrations
I ran through a calibration exercise for
the IOS slits. Here is my data. I have moved
each set to the midpoint of the largest (5mm)
79
Thu Jul 16 14:06:56 2009
Damien Gallop
MCIS vacuum trip overnight
The MCIS vacuum system tripped last night
again. Fortunately the operators
noticed it and restarted stuff. Otherwise
78
Wed Jul 15 16:37:01 2009
Damien Gallop
Bias for IOS emittance rig
Graham looked up the list of IOS bias assignments.
None was form the emittance rig. I quickly
tested the list in ILT, but nothing jumped
77
Wed Jul 15 14:41:25 2009
Damien Gallop
18O5+ survey
A/q = 3.6 Field = 888.6G FC6 = 10nA
Two emittance scans, one with the
as-is emittance rig, one with a manually
76
Wed Jul 15 10:52:25 2009
Damien Gallop
18O6+ survey
A/q = 3 Field = 813.2 FC6 = 2.9nA
Beam is too faint for a good emittance
scan, but it's visible. Redo with reverse
7x
75
Wed Jul 15 10:51:25 2009
Damien Gallop
18O7+ survey
A/q = 2.571 Field = 752.9 FC6 = 88pA
74
Wed Jul 15 10:41:23 2009
Damien Gallop
18O8+ survey
A/q = 2.25 Field = 704.7G FC6 = <pA
Well, it's there, but pretty faint.
The attached stripchart shows no beam then
Goto page
Previous
1
,
2
,
3
...
21
, 22,
23
,
24
,
25
,
26
Next
ELOG V2.9.2-2455