OLIS Logbook General
  General, Page 22 of 26  Not logged in ELOG logo
ID Datedown Author Type Category Subject Text Attachments
  93   Thu Jul 16 16:33:28 2009 Damien Gallop  18O3+ surveyA/q = 6 Field = 1147.2 FC6 = 39.3enA  grab.k17100.pnggrab.e17104.pnggrab.E17109.png 
  92   Thu Jul 16 16:15:39 2009 Damien Gallop  16O3+ surveyA/q = 5.3333 Field = 1081.6G FC6 = 110nA  grab.F17014.pnggrab.D17019.pnggrab.E17026.png 
  91   Thu Jul 16 15:58:53 2009 Damien Gallop  18O4+ surveyA/q = 4.5 Field = 993.5G FC6 = 20enA  grab.Q16857.pnggrab.l16862.pnggrab.r16890.png 
  90   Thu Jul 16 15:49:46 2009 Damien Gallop  16O4+ surveyA/q = 4 Field = 936.7 FC6 = 54.0enA  grab.W16723.pnggrab.F16727.pnggrab.l16731.png 
  89   Thu Jul 16 15:41:35 2009 Damien Gallop  18O5+ surveyA/q = 3.6 Field = 888.6G FC6 = 6.2enA  grab.d16597.pnggrab.v16602.pnggrab.z16609.png 
  88   Thu Jul 16 15:38:58 2009 Damien Gallop  16O5+ surveyA/q = 3.2 Field = 837.7G FC6 = 14.5enA  grab.a16526.pnggrab.l16532.pnggrab.N16536.png 
  87   Thu Jul 16 15:22:51 2009 Damien Gallop  18O6+ surveyA/q = 3 Field = 811.2G FC6 = 1.6nA
Not quite enough beam for an emittance
scan.
 grab.Z16300.png 
  86   Thu Jul 16 15:11:16 2009 Damien Gallop  16O6+ surveyA/q = 2.6667 Field = 764.7G FC6 = 3.0nA  grab.e16164.pnggrab.z16169.pnggrab.a16173.png 
  85   Thu Jul 16 14:50:38 2009 Damien Gallop  18O7+ surveyA/q = 2.5714 Field = 751.1G FC6 = 40epA
No emittance scan possible.
  
  84   Thu Jul 16 14:46:52 2009 Damien Gallop  16O7+ surveyA/q = 2.2857 Field = 708.0G FC6 = 70epA
(noisy)
No emittance scan possible.
  
  83   Thu Jul 16 14:44:06 2009 Damien Gallop  18O8+ surveyA/q = 2.25 Field = 702.5G FC6 = not visible
It looks like last night's vacuum
trip is biting us here.
  
  82   Thu Jul 16 14:41:46 2009 Damien Gallop  16O8+ surveyA/q = 2 Field = 662.3G FC6 = 150epA (unstable)
No emittance scan possible.
  
  81   Thu Jul 16 14:25:27 2009 Damien Gallop  18O4+ surveyA/q = 4.5 Field = 993.5G FC6 = 24.0enA  grab.x15815.pnggrab.p15822.pnggrab.x15826.png 
  80   Thu Jul 16 14:11:43 2009 Damien Gallop  MCOL3 slits calibrationsI ran through a calibration exercise for
the IOS slits. Here is my data. I have moved
each set to the midpoint of the largest (5mm)
 grab.k15763.pnggrab.h15767.pnggrab.J15771.png 
  79   Thu Jul 16 14:06:56 2009 Damien Gallop  MCIS vacuum trip overnightThe MCIS vacuum system tripped last night
again. Fortunately the operators
noticed it and restarted stuff. Otherwise
 grab.X15685.png 
  78   Wed Jul 15 16:37:01 2009 Damien Gallop  Bias for IOS emittance rigGraham looked up the list of IOS bias assignments.
None was form the emittance rig. I quickly
tested the list in ILT, but nothing jumped
 grab.wu7505.pnggrab.Vo7510.pnggrab.le7613.pnggrab.TN7617.png 
  77   Wed Jul 15 14:41:25 2009 Damien Gallop  18O5+ surveyA/q = 3.6 Field = 888.6G FC6 = 10nA
Two emittance scans, one with the
as-is emittance rig, one with a manually
 grab.Nr6887.pnggrab.ag6892.pnggrab.sV7547.pnggrab.Sg7555.png 
  76   Wed Jul 15 10:52:25 2009 Damien Gallop  18O6+ surveyA/q = 3 Field = 813.2 FC6 = 2.9nA
Beam is too faint for a good emittance
scan, but it's visible. Redo with reverse
 7x 
  75   Wed Jul 15 10:51:25 2009 Damien Gallop  18O7+ surveyA/q = 2.571 Field = 752.9 FC6 = 88pA   
  74   Wed Jul 15 10:41:23 2009 Damien Gallop  18O8+ surveyA/q = 2.25 Field = 704.7G FC6 = <pA
Well, it's there, but pretty faint.
The attached stripchart shows no beam then
 grab.dg7993.png 
ELOG V2.9.2-2455