53
Wed Jul 8 17:47:26 2009
Damien Gallop
Routine
General
18O4+ emittance scans
First up is a check scan of 18O4+. There
is a definite vertical offset compared to
earlier today. Otherwise, it correlates well
57
Wed Jul 8 18:38:21 2009
Damien Gallop
Routine
General
18O4+ emittance scan
A/q = 4.5 FC6 = 29.5nA MB = 1041.8G @ 62.4A
48
Wed Jul 8 09:22:07 2009
Damien Gallop
Routine
General
18O4+ beam growth overnight
After accessing the OLIS cage and opening
the 18O source gas valve, I restarted the
Supernanogan source last evening around 18:00
93
Thu Jul 16 16:33:28 2009
Damien Gallop
18O3+ survey
A/q = 6 Field = 1147.2 FC6 = 39.3enA
56
Wed Jul 8 18:20:43 2009
Damien Gallop
Routine
General
18O3+ emittance scan
A/q = 6 FC6 = 49.5nA MB = 1201.4G @ 73.1A
95
Thu Jul 16 16:50:41 2009
Damien Gallop
18O2+ survey
A/q = 9 Field = 1405.0G FC6 = 55enA
55
Wed Jul 8 18:12:25 2009
Damien Gallop
Routine
General
18O2+ emittance scan
A/q = 9 FC6 = 50.0nA MB = 1470.8G @ 90.8A
97
Thu Jul 16 17:09:52 2009
Damien Gallop
18O1+ survey
A/q = 18 Field = 1987.1 FC6 = 161nA
54
Wed Jul 8 17:58:02 2009
Damien Gallop
Routine
General
18O1+ emittance scan
Here we go. A/q = 18 FC6 = 141.0nA MB =
2078G @ 130.2A
9
Thu Jun 4 10:46:37 2009
Damien Gallop
Routine
General
18O source operation overnight
The MWS delivered 18O overnight, mostly
onto FC6. Sophia complained about source
stability this morning. It definitely could
45
Mon Jul 6 17:34:24 2009
Damien Gallop
Routine
General
18O background studies
Well... my browser blew away just before
I submitted version one of this entry. Let's
try again.
6x
139
Tue Sep 15 20:02:46 2009
Keerthi
17O8+ on FC6 from MCIS
0.4nA of 17O+8 is sitting on FC6. Development
will continue tomorrow.
181
Fri Nov 6 11:17:54 2009
Damien Gallop
17O3+ setup to DRAGON
As noted, we handed over the beam to our
users yesterday by noon. Setup to DRAGON
is continuing. The report this morning that
420
Fri Aug 19 10:01:52 2011
Damien Gallop
17O3+ from MCIS to DRAGON
Setup in progress. No foil at M:5. Source
has been running since yesterday. Note that
source was opened recently for MRO. Vacuum
421
Mon Aug 22 09:49:34 2011
Damien Gallop
17O3+ from MCIS to DRAGON
Delivery continues. The attached vacuum
trar suggests that this is about as good
as it's going to get. On the other hand,
422
Wed Aug 24 10:49:41 2011
Damien Gallop
17O3+ from MCIS to DRAGON
Delivery continues. There were several
"PV1" trips over the past several
days. ICR now has a recipe for resetting
423
Thu Aug 25 10:54:34 2011
Damien Gallop
17O3+ from MCIS to DRAGON
Delivery continues.
424
Mon Aug 29 10:03:05 2011
Damien Gallop
17O3+ from MCIS to DRAGON
Delivery continues on autopilot. Looking
good.
ICR noted that a seemingly unusual number
425
Tue Aug 30 10:01:30 2011
Damien Gallop
17O3+ from MCIS Reserved
We are on orders to retain OLIS for accelerator
development. The switchover to 58Ni, scheduled
for this morning, is on hold.
186
Mon Nov 16 10:00:41 2009
Damien Gallop
17O3+ beam to DRAGON end of run this morning
DRAGON declared EOB at around 08:00 today.
Source and beam were switched to 21Ne4+ for
calibration studies.