OLIS Logbook General
  General, Page 21 of 26  Not logged in ELOG logo
ID Date Author Type Category Subjectdown Text Attachments
  53   Wed Jul 8 17:47:26 2009 Damien GallopRoutineGeneral18O4+ emittance scansFirst up is a check scan of 18O4+. There
is a definite vertical offset compared to
earlier today. Otherwise, it correlates well
 grab.Jj2874.pnggrab.fz2878.pnggrab.ND2931.pnggrab.pH2935.pnggrab.oY2939.png 
  57   Wed Jul 8 18:38:21 2009 Damien GallopRoutineGeneral18O4+ emittance scanA/q = 4.5 FC6 = 29.5nA MB = 1041.8G @ 62.4A  grab.Cb3157.pnggrab.wO3161.png 
  48   Wed Jul 8 09:22:07 2009 Damien GallopRoutineGeneral18O4+ beam growth overnightAfter accessing the OLIS cage and opening
the 18O source gas valve, I restarted the
Supernanogan source last evening around 18:00
 grab.hD1461.png 
  93   Thu Jul 16 16:33:28 2009 Damien Gallop  18O3+ surveyA/q = 6 Field = 1147.2 FC6 = 39.3enA  grab.k17100.pnggrab.e17104.pnggrab.E17109.png 
  56   Wed Jul 8 18:20:43 2009 Damien GallopRoutineGeneral18O3+ emittance scanA/q = 6 FC6 = 49.5nA MB = 1201.4G @ 73.1A  grab.Pc3095.pnggrab.Oi3099.png 
  95   Thu Jul 16 16:50:41 2009 Damien Gallop  18O2+ surveyA/q = 9 Field = 1405.0G FC6 = 55enA  grab.N17330.pnggrab.Y17335.pnggrab.w17339.png 
  55   Wed Jul 8 18:12:25 2009 Damien GallopRoutineGeneral18O2+ emittance scanA/q = 9 FC6 = 50.0nA MB = 1470.8G @ 90.8A  grab.LL3034.pnggrab.Yj3038.png 
  97   Thu Jul 16 17:09:52 2009 Damien Gallop  18O1+ surveyA/q = 18 Field = 1987.1 FC6 = 161nA  grab.b17471.pnggrab.r17475.pnggrab.R17480.png 
  54   Wed Jul 8 17:58:02 2009 Damien GallopRoutineGeneral18O1+ emittance scanHere we go. A/q = 18 FC6 = 141.0nA MB =
2078G @ 130.2A
 grab.QR2996.pnggrab.dm3000.png 
  9   Thu Jun 4 10:46:37 2009 Damien GallopRoutineGeneral18O source operation overnightThe MWS delivered 18O overnight, mostly
onto FC6. Sophia complained about source
stability this morning. It definitely could
  
  45   Mon Jul 6 17:34:24 2009 Damien GallopRoutineGeneral18O background studiesWell... my browser blew away just before
I submitted version one of this entry. Let's
try again.
 6x 
  139   Tue Sep 15 20:02:46 2009 Keerthi  17O8+ on FC6 from MCIS0.4nA of 17O+8 is sitting on FC6. Development
will continue tomorrow.
 grab.I24583.png 
  181   Fri Nov 6 11:17:54 2009 Damien Gallop  17O3+ setup to DRAGONAs noted, we handed over the beam to our
users yesterday by noon. Setup to DRAGON
is continuing. The report this morning that
 Picture_9.png 
  420   Fri Aug 19 10:01:52 2011 Damien Gallop  17O3+ from MCIS to DRAGONSetup in progress. No foil at M:5. Source
has been running since yesterday. Note that
source was opened recently for MRO. Vacuum
 Picture_20.pngPicture_21.png 
  421   Mon Aug 22 09:49:34 2011 Damien Gallop  17O3+ from MCIS to DRAGONDelivery continues. The attached vacuum
trar suggests that this is about as good
as it's going to get. On the other hand,
 Picture_25.png 
  422   Wed Aug 24 10:49:41 2011 Damien Gallop  17O3+ from MCIS to DRAGONDelivery continues. There were several
"PV1" trips over the past several
days. ICR now has a recipe for resetting
 Picture_20.pngPicture_21.pngPicture_22.png 
  423   Thu Aug 25 10:54:34 2011 Damien Gallop  17O3+ from MCIS to DRAGONDelivery continues.  Picture_24.pngPicture_25.pngPicture_26.pngPicture_27.pngPicture_28.png 
  424   Mon Aug 29 10:03:05 2011 Damien Gallop  17O3+ from MCIS to DRAGONDelivery continues on autopilot. Looking
good.
ICR noted that a seemingly unusual number
  
  425   Tue Aug 30 10:01:30 2011 Damien Gallop  17O3+ from MCIS ReservedWe are on orders to retain OLIS for accelerator
development. The switchover to 58Ni, scheduled
for this morning, is on hold.
 Picture_32.png 
  186   Mon Nov 16 10:00:41 2009 Damien Gallop  17O3+ beam to DRAGON end of run this morningDRAGON declared EOB at around 08:00 today.
Source and beam were switched to 21Ne4+ for
calibration studies.
 Picture_1.png 
ELOG V2.9.2-2455