OLIS Logbook General
  General, Page 19 of 26  Not logged in ELOG logo
ID Date Author Type Category Subjectdown Text Attachments
  203   Thu Dec 3 14:12:56 2009 Damien Gallop  20Ne1+ at 28keV for 8pi delivery continuesBeam was idle overnight. We took the beam
for a while this morning, and ran a mass
scan. We opted to not go into the cage to
 Picture_20.png 
  204   Fri Dec 4 09:58:08 2009 Damien Gallop  20Ne1+ at 28keV for 8pi delivery completeMike declared successful EOB this morning.
"Best beam I ever used" or something
like that! EOB emittance and mass scans attached.
 grab.InU319.pnggrab.YPZ323.pnggrab.RXD329.pnggrab.aGj522.pngPicture_1.png 
  202   Wed Dec 2 19:03:55 2009 Damien Gallop  20Ne1+ at 28keV for 8pi deliveryThe source ran well overnight and today.
There is an issue with an ILE Faraday cup.
Tuning is ended for today, and beam is on
 Picture_19.png 
  201   Tue Dec 1 12:33:58 2009 Damien Gallop  20Ne1+ at 28keV for 8piBy agreement, we are providing OLIS beam
to the Beam Delivery group for the purpose
of checking out transmission in the 8pi line.
 8x 
  511   Mon Sep 14 11:21:16 2015 Keerthi JayamannaRoutineGeneral20Ne+2 beam saved20Ne+2 beam optics saved as 150914_1117_ios0iosfc6.snap   
  3   Fri May 15 14:12:45 2009 Geoff Wight  1st testtest   
  449   Thu Oct 6 15:15:09 2011 Damien Gallop  19F/40Ar from MCIS for Beam DevelopmentSlit calibration exercise was wound up
this morning. MCIS source gases were reconfigured
with 19F and 40Ar by request. A "cocktail"
 Picture_4.png 
  451   Mon Oct 17 11:33:03 2011 Damien Gallop  19F/38Ar from MCIS for Beam DevelopmentSource set up for a cocktail beam since
yesterday, Sunday.
  
  452   Tue Oct 18 10:27:44 2011 Damien Gallop  19F/38Ar from MCIS for Beam DevelopmentCocktail beams continue today.  Picture_7.png 
  62   Wed Jul 8 19:51:33 2009 Damien GallopRoutineGeneral18On+ summary for the dayThe 18O source gas bottle is online. The
ion source was optimized for 18O4+ and kept
the same throughout. Emittance scans of each
 grab.TF3397.pnggrab.fu3402.pnggrab.Tk3406.png 
  65   Fri Jul 10 11:46:55 2009 Damien GallopRoutineGeneral18On+ frequency scans & resonancesThe Supernanogan was restarted this morning,
after last night's power bump. 18O4+ on FC6,
cooking for about an hour. Looks very good.
 Picture_18.png 
  66   Fri Jul 10 11:47:07 2009 Damien GallopRoutineGeneral18On+ frequency scans & resonancesThe Supernanogan was restarted this morning,
after last night's power bump. 18O4+ on FC6,
cooking for about an hour. Looks very good.
 Picture_18.png 
  47   Tue Jul 7 17:47:14 2009 Damien GallopRoutineGeneral18On+ beam & emittanceAs noted earlier, we have 17O and 18O source
gas attached to the Supernanogan source chamber.
Both are valved off presently. The source
  
  472   Fri Dec 14 17:30:47 2012 Keerthi Jayamanna  18OH2 and 40Ar+2 delivaryDuring the last week we delivered 18O+2
from microwave ion source to Ritu.
Over the week end changed to 40Ar+2.
  
  74   Wed Jul 15 10:41:23 2009 Damien Gallop  18O8+ surveyA/q = 2.25 Field = 704.7G FC6 = <pA
Well, it's there, but pretty faint.
The attached stripchart shows no beam then
 grab.dg7993.png 
  83   Thu Jul 16 14:44:06 2009 Damien Gallop  18O8+ surveyA/q = 2.25 Field = 702.5G FC6 = not visible
It looks like last night's vacuum
trip is biting us here.
  
  100   Fri Jul 17 09:47:16 2009 Damien Gallop  18O8+ recheckGo fishing in the range 2.24-2.26, but
no fish in this pond this time. However,
there is a relatively strong beam at 2.3.
  
  63   Thu Jul 9 16:07:56 2009 Damien GallopRoutineGeneral18O8+ frequency scansKeerthi did some 18On+ frequency scans
this morning. He observed 18O8+! I am attempting
to repeat it myself now. Reverse bias on
 6x 
  61   Wed Jul 8 19:13:15 2009 Damien GallopRoutineGeneral18O8+ emittance scanA/q = 2.25 FC6 at reverse bias MB = 736.9G
@ 42.9A
Not enough intensity for an emittance
 grab.Ah3293.pnggrab.ed3302.pnggrab.Nc3298.png 
  64   Fri Jul 10 09:55:25 2009 Damien GallopRoutineGeneral18O8+ beam overnightHere is a striptool of 18O8+ beam (magenta
trace) last evening from about 18:00 to 22:30
when there was a large power bump coincident
 grab.N10241.png 
ELOG V2.9.2-2455