OLIS Logbook General
  General, Page 13 of 26  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Type Category Subjectdown
  506   Tue Nov 25 12:23:28 2014 Keerthi JayamannaRoutineGeneral76Se+13 tune saved

141125_1159_OLIS_76Se+13.snap is saved in reference directory.

El=3480/4303V

MCIS:YCB1=110

MCIS:XCB1=190

MCIS:CCB1=300

Frequency = 14.44765GHz

Amplitude = -10.880

TET FP= 9.8W

TWT RP = 1.8W

 

  317   Thu Jul 22 09:25:21 2010 Damien Gallop  74Ge1+ to TITAN

The Supernanogan is producing 74Ge using the heater source, a first for the Supernanogan. Development done over the last couple of days and completed yesterday. Tuning using mass 76 (76Ge or 76Se?) was done last night. Energy is set at 12.24kV, same as previous 12C2+ run. Beam is being used as TITAN pilot beam for their 74Kr run.

Attachment 1: Picture_3.png
Picture_3.png
  318   Fri Jul 23 13:00:04 2010 Damien Gallop  74Ge1+ to TITAN

Beam remained on FC6 overnight. Beam was used for a tune check this morning. At noon today beam was switched to 4He.

Later... Outcome of 4He development with Supernanogan: beam comes with other isotopes. e.g. 12C3+ and 16O4+. Verdict: 4He1+ beam is better produced with the MWS.

Later... By request, set up source for 74Ge beam again. ~30pA on FC6 by ~midnight.

Attachment 1: Picture_4.png
Picture_4.png
Attachment 2: Picture_3.png
Picture_3.png
  319   Mon Jul 26 09:41:46 2010 Damien Gallop  74Ge1+ to TITAN

Beam is sitting on FC6 presently. Good source operation over the weekend. Some pics to come. RIB delivery to TITAN ended at 08:30 this morning. OLIS is scheduled for a beam switch tomorrow morning.

Later... A power bump knocked us out cold again. It appears that the Safety Enable bit was lost.

  426   Tue Aug 30 16:40:14 2011 Damien Gallop  58Ni1+ from MWS to TITAN Setup

Source switchover from MCIS to MWS. Support gases and liners were pre-fitted. Source lit. Optics set for 20keV operation. ~50pA on FC6.

Attachment 1: Picture_33.png
Picture_33.png
Attachment 2: Picture_34.png
Picture_34.png
Attachment 3: Picture_36.png
Picture_36.png
  427   Wed Aug 31 12:12:39 2011 Damien Gallop  58Ni1+ from MWS to TITAN Setup

Beam on FC6 drifted overnight. Touch up a few things, notably the EE. 25pA on FC6 presently. I also increased microwave power for effect.

Later... about 25pA on FC6. Somewhat noisy, but also stable. I left microwave at 700W. Beam handed over to ICR at ~13:15.

A note about mass flow controller. The new Hastings controllers do indeed shut off completely at zero setting. It should be noted that control in the sub-1sccm region is challenging. Move in 0.01 steps. I found that everything was fine down to 0.15sccm. The next step after that, i.e. to 0.14, closed the flow entirely. Not a crisis in this situation.

Attachment 1: Picture_37.png
Picture_37.png
Attachment 2: Picture_38.png
Picture_38.png
  428   Thu Sep 1 10:01:25 2011 Damien Gallop  58Ni1+ from MWS to TITAN

Beam was established yesterday. It has grown nicely overnight.

Attachment 1: Picture_39.png
Picture_39.png
  429   Fri Sep 2 10:04:55 2011 Damien Gallop  58Ni1+ from MWS to TITAN

Beam idled overnight. Average ~50pA at FC6. About half that on ILE2T:FC3 presently. Setup on TITAN side in progress.

Later... ICR is concerned about the OLIS separator magnet wandering during the day. It's sunny today, so I would expect a little more wandering than on a rainy day. Also, they have significantly higher current at A/q >58.1 and asked if there could be another mass in the mix. Checking.

Later... TITAN takes coffee break. Opportunity to do a mass scan and also tweak source. Confirmed that centroid of mass peak is ~58.2. (Note: Slits left open for scan, so resolution is low.)

Note: Since this morning magnet adjustments, there are some 200pA of beam at FC6.

Attachment 1: Picture_40.png
Picture_40.png
Attachment 2: Picture_41.png
Picture_41.png
Attachment 3: Picture_42.png
Picture_42.png
Attachment 4: Picture_43.png
Picture_43.png
Attachment 5: Picture_45.png
Picture_45.png
Attachment 6: Picture_46.png
Picture_46.png
Attachment 7: Picture_47.png
Picture_47.png
Attachment 8: Picture_48.png
Picture_48.png
Attachment 9: Picture_49.png
Picture_49.png
  430   Tue Sep 6 16:37:24 2011 Damien Gallop  58Ni1+ from MWS to TITAN

Pilot beam delivery continues. Keerthi came in over the Labor Day weekend to help out on something.

Beam is scheduled for one more day. A source change is scheduled for 20:30 tomorrow.

Attachment 1: Picture_50.png
Picture_50.png
  431   Wed Sep 7 09:50:20 2011 Damien Gallop  58Ni1+ from MWS to TITAN

Delivery continues. Source change scheduled for 20:30 this evening.

Attachment 1: Picture_52.png
Picture_52.png
  400   Mon Jun 27 10:20:41 2011 Damien Gallop  58Ni from MCIS to TITAN

From MCIS. It looks like things went fairly well over the weekend for them. An interlock glitch on MCIS:IV1 this morning, source pressure went slightly above MCIS:IG1 "Good" threshold. I have suggested to Tiffany that raising the "Good" threshold to 1e-7 might be a good idea. Because we are intentionally running with MCIS:TP3 off, the source pressure is higher. It's right on the edge of the current "Good" threshold. Attached is a trar of the MCIS pressure trend, which looks healthy.

Attachment 1: Picture_1.png
Picture_1.png
Attachment 2: Picture_2.png
Picture_2.png
  401   Tue Jun 28 09:32:09 2011 Damien Gallop  58Ni from MCIS to TITAN

Beam mostly idle overnight. Things are resuming now.

Attachment 1: Picture_4.png
Picture_4.png
  402   Wed Jun 29 09:45:50 2011 Damien Gallop  58Ni from MCIS to TITAN

Last hours and minutes. Going well. Documentation appended. Users have requested beam until noon.

Note: We are using the MWS bias and EE power supplies on the Supernanogan source for this run, to provide source bias and also sputter chamber bias for the Supernanogan.

Attachment 1: Picture_5.png
Picture_5.png
Attachment 2: Picture_6.png
Picture_6.png
Attachment 3: Picture_7.png
Picture_7.png
Attachment 4: Picture_8.png
Picture_8.png
Attachment 5: Picture_9.png
Picture_9.png
Attachment 6: Picture_10.png
Picture_10.png
Attachment 7: Picture_11.png
Picture_11.png
Attachment 8: Picture_1.png
Picture_1.png
  399   Fri Jun 24 15:11:20 2011 Damien Gallop  58Ni from MCIS to FC6 Setup

OLIS was switched from 22Ne2+ (MWS) to 58Ni+1 (MCIS). Works like magic. 100epA presently.

  321   Wed Jul 28 09:23:57 2010 Damien Gallop  4He1+ for TIGRESS

Source switchover went quite well yesterday morning. About 6nA of beam on FC6. Beam idle overnight. Tuning has resumed now.

Attachment 1: Picture_1.png
Picture_1.png
  322   Thu Jul 29 15:31:21 2010 Damien Gallop  4He1+ for TIGRESS

Beam in use intermittently.

  331   Tue Aug 10 09:30:36 2010 Damien Gallop  4He1+ for SCC Development

Beam idle overnight, and grew nicely. Source tweaked up and throttled back a little while ago. SCC development expected to continue today.

Attachment 1: Picture_2.png
Picture_2.png
  332   Wed Aug 11 10:35:03 2010 Damien Gallop  4He1+ for SCC Development

Beam used into last evening, then idle overnight. Nice and stable. Maintenance Day for the cyclotron and ISAC.

Attachment 1: Picture_1.png
Picture_1.png
  333   Fri Aug 13 09:27:49 2010 Damien Gallop  4He1+ for SCC Development

MWS is running nicely. SCC development continues. This is scheduled to end on this coming Tuesday morning. It will likely continue for a couple of days, after which there would be a beam switch to 16O2+ from the MWS for TUDA-II setup.

Attachment 1: Picture_12.png
Picture_12.png
  338   Mon Sep 20 09:34:44 2010 Damien Gallop  4He1+ for DRAGON

MCIS Development finished Friday evening. OLIS switched to MWS operation and setup began for 4He1+ delivery to DRAGON. Beam handed over to experiment last night.

ELOG V2.9.2-2455