OLIS Logbook General
  General, Page 12 of 26  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
IDdown Date Author Type Category Subject
  293   Sat Jun 12 10:20:14 2010 Damien Gallop  15N4+ to TIGRESS done

Delivery to TIGRESS ended this morning as scheduled. ICR took nice emittance scans and is completing a target snapshot now. Canister still at -22"Hg and MCIS at 7.3e-8 Torr.

Chance to snap some wirescans. Attached.

Attachment 1: Picture_1.png
Picture_1.png
Attachment 2: Picture_2.png
Picture_2.png
Attachment 3: Picture_3.png
Picture_3.png
Attachment 4: grab.X18646.png
grab.X18646.png
Attachment 5: grab.a18624.png
grab.a18624.png
Attachment 6: grab.b18676.png
grab.b18676.png
Attachment 7: grab.p18697.png
grab.p18697.png
Attachment 8: grab.V18720.png
grab.V18720.png
Attachment 9: grab.N18741.png
grab.N18741.png
Attachment 10: grab.C18766.png
grab.C18766.png
Attachment 11: grab.F18788.png
grab.F18788.png
Attachment 12: grab.g18469.png
grab.g18469.png
Attachment 13: grab.O18473.png
grab.O18473.png
  292   Fri Jun 11 09:21:24 2010 Damien Gallop  15N4+ to TIGRESS

Delivery of 15N4+ to TIGRESS continues. Source gas canister is still at ~-22"Hg, and MCIS pressure is 7.2e-8 Torr. ICR reported intensity drops a couple of times this morning. The attached Stripchart suggests beam from the source is down to about a third from status quo. We will look into it now.

Attachment 1: Picture_1.png
Picture_1.png
  291   Thu Jun 10 09:17:42 2010 Damien Gallop  15N4+ to TIGRESS

Delivery to TIGRESS began yesterday or so. ICR reported beam intensity drops overnight. I'll look at it presently. Meanwhile, canister pressure is still ~-22"Hg and MCIS pressure is 7.09e-8 Torr.

Later... Check source at request of ICR. It looks mighty fine. Slight tweaks on RF, but really no great change. FC6 was and is 200enA, though it was around 80enA this morning.

Attachment 1: Picture_1.png
Picture_1.png
Attachment 2: Picture_2.png
Picture_2.png
Attachment 3: Picture_3.png
Picture_3.png
  290   Wed Jun 9 10:07:33 2010 Damien Gallop  15N4+ to TIGRESS

Setup into ISAC-II began last night. Tuning is in progress now. Beam on FC6 overnight. Canister pressure is -22"Hg and MCIS pressure=7.1e-8 Torr. Pressure showed correlation with temperature. It is overcast today and cool, suggesting a fairly flat response today.

Attachment 1: Picture_7.png
Picture_7.png
  289   Tue Jun 8 09:27:54 2010 Damien Gallop  15N4+ to TIGRESS

User tuning began Sunday night. Beam physics expert chose to retire the IOS:Q1 defeat, as he did not know until yesterday that it existed. He discovered it after attempting to retune yesterday around noon from scratch and making a mess, notwithstanding Keerthi's clear instruction to leave it alone. He also does not know that Rick developed a tune for this, which provides cleaner transmission than the "book" tune. Pity. Presently there are some 75enA of beam at FC6. That should be enough. Note that there were some 90enA with the "defeat" tune in place, prior to changing the IOS tune. Canister is at ~-22"Hg, and MCIS pressure at ~7.0e-8 Torr at ~09:00.. ICR is tuning through presently.

Attachment 1: Picture_4.png
Picture_4.png
Attachment 2: Picture_5.png
Picture_5.png
  288   Mon Jun 7 10:36:14 2010 Damien Gallop  15N setup over the weekend

Keerthi set up the Supernanogan for 15N operation and destined for TIGRESS, using two source gas options: a miniature bottle of enriched 15N2 and a canister with a charge of research-grade 14N2. The canister is similar to the one we used for the 33S run to DRAGON, which finished Saturday morning. Canister is at -22"Hg and MCIS at 7.27e-8 Torr. A couple of beam stability tests were conducted at 15N4+ and 15N6+. Bob can choose which one he prefers to use. 15N4+ is selected and tuned through IOS up to the RFQ presently (~10:30 am).

Later... Bob reported at the Beam Delivery meeting that the 33S6+ beam was a very nice beam. We appreciate hearing it.

Attachment 1: Picture_2.png
Picture_2.png
  287   Fri Jun 4 09:30:48 2010 Damien Gallop  33S to DRAGON

Delivery of 33S6+ continues to DRAGON for the final day. Some online tuning of the line overnight. Source gas canister pressure remains at ~-20"Hg, and MCIS pressure is at 7.1e-8 Torr.

Attachment 1: Picture_2.png
Picture_2.png
  286   Thu Jun 3 09:29:11 2010 Damien Gallop  33S to DRAGON

33S6+ delivery to DRAGON continues until Saturday morning. All the signs are that beam is excellent. Source gas canister is still at ~-20"Hg, and MCIS vacuum is at 7.0e-8 Torr.

Attachment 1: Picture_1.png
Picture_1.png
  285   Wed Jun 2 09:19:04 2010 Damien Gallop  33S to DRAGON

33S6+ delivery to DRAGON continues. It is Maintenance Day for everybody else today. Source gas canister pressure = -20"Hg. MCIS pressure = 7.7e-8 Torr.

  284   Tue Jun 1 09:12:39 2010 Damien Gallop  33S to DRAGON

33S6+ delivery to DRAGON continues. Looks like there was an RF tweak overnight. Source gas canister still at ~-20"Hg. MCIS vacuum at 7.4e-8 Torr.

Attachment 1: Picture_2.png
Picture_2.png
  283   Mon May 31 09:18:39 2010 Damien Gallop  33S to DRAGON

Delivery of 33S6+ to DRAGON continues. A couple of RF tweaks done over the weekend. Source gas canister pressure at -20"Hg. MCIS pressure at 7.3e-8 Torr. At this rate, we could deliver 33S until approximately forever.

Attachment 1: Picture_2.png
Picture_2.png
  282   Fri May 28 11:02:59 2010 Damien Gallop  33S to DRAGON

Beam tuning in progress. Source gas canister at -20"Hg. MCIS pressure at 7.62e-8 Torr.

Attachment 1: Picture_1.png
Picture_1.png
  281   Thu May 27 09:11:10 2010 Damien Gallop  33S Development and Handover

33S on FC6 overnight. Preparing to send beam to DRAGON now, and confirm isotope.

Source gas pressure gauge on canister = -20"Hg. MCIS pressure = 7.8e-8 Torr.

Attachment 1: Picture_2.png
Picture_2.png
  280   Wed May 26 18:16:10 2010 Damien Gallop  33S Development

Some 3enA of beam on FC6 presently. Let it sit.

Attachment 1: grab.Cm6004.png
grab.Cm6004.png
  279   Tue May 25 22:02:41 2010 Keerthi Jayamanna  33S spectrum

33S spectrum is saved as 33S_spectrum.dat 

  278   Tue May 25 11:58:02 2010 Keerthi Jayamanna  33S dev

after 24 hours background spectrum saved as "BackgroungNo33S003.dat"

RF Amplitude :7.767 , RFoutput power= 5W, Output power (dB)=36.4

  277   Tue May 25 11:28:00 2010 Keerthi Jayamanna  33D dev

after 24 hours background spectrum saved as "BackgroungNo33S002.dat"

RF Amplitude :1.553 , RFoutput power= 0, Output power (dB)=0  

  276   Tue May 25 00:19:18 2010 Keerthi Jayamanna  33S

 

Finally got something going. YCB1 short to the ground. YCB common plate connected to YCB1 power supply. We were lucky. Polarity was right. Ran the source with no 33S.
Saved file as “backgroundNo33S.dat” No optics set yet. SO2 connected not open yet. 33S 17% is in the oven, but not heated yet.
  275   Mon May 24 22:42:51 2010 Keerthi Jayamanna  33S development

Tried to see the background before 33S installation. Found few problems: MCIS:YCB1 does not hold more than 58V.

Very difficult to transport the beam without YCB1. Need to find a solution. Open and fix it is not an option even though we have a ready spare. It will take two weeks to get the vacuum back.

------------------------------

Outgoing TIGRESS experiment was the occasion for another ISAC milestone, 8MeV/u through the SCC for the first time just around midnight last Friday, May 21st. This also represented the first 8MeV/u beam to an experiment. And we can proudly say that OLIS beam was used. TIGRESS run ended at 08:30 as scheduled. Attached is a trar graph of beam on FC6, snapped periodically throughout the run. As before, you can see a small daily variation likely related to temperature of NA-LCW. There were reports of HPL tests this past Thursday and Friday. Evidently no effect over here.

 

Attachment 1: Picture_1.png
Picture_1.png
  274   Wed May 19 09:55:51 2010 Damien Gallop  20Ne1+ at 40.8keV for TIGRESS

ISAC-I tuning done yesterday. TBC today into ISAC-II. Beam very nice overnight.

Attachment 1: Picture_6.png
Picture_6.png
ELOG V2.9.2-2455