OLIS Logbook General
  General  Not logged in ELOG logo
Message ID: 43     Entry time: Fri Jul 3 10:29:15 2009
Author: Damien Gallop 
Type: Routine 
Category: General 
Subject: RF frequency scans versus each charge state of 16O cont'd. 

16O2+ beam on FC6 = 10nA as before. Move to 16O3+ A/q = 5.33...

A frequency scan between 13 & 14GHz. I panned closer around two peaks at 13.11 and 13.12GHz. Best frequency so far is 13.1321GHz, which provides a reasonably stable 150pA of 16O3+.

Later... more scans, etc. One of several possible solutions for 16O3+: ~450pA at 13.6348GHz. Let it cook for a while.

Attachment 1: grab.Cr7150.png  19 kB  Uploaded Fri Jul 3 12:54:40 2009  | Show | Show all
Attachment 2: grab.yi7257.png  23 kB  Uploaded Fri Jul 3 13:40:03 2009  | Show | Show all
Attachment 3: grab.vt7264.png  21 kB  Uploaded Fri Jul 3 13:40:14 2009  | Hide | Show all
grab.vt7264.png
Attachment 4: grab.vP7271.png  10 kB  Uploaded Fri Jul 3 13:40:25 2009  | Show | Show all
ELOG V2.9.2-2455