OLIS Logbook General
  General  Not logged in ELOG logo
Message ID: 273     Entry time: Tue May 18 09:15:16 2010
Author: Damien Gallop 
Type:  
Category:  
Subject: 20Ne1+ at 40.8keV for TIGRESS setup 

Prepare to switch beam from 22Ne2+ to 20Ne1+. Skimmers from 22Ne2+ run shown below. Table of tune options below. We will be using the Rick Tune.

Device Present Tune Scaled Scaled   Rick Tune Scaled   Web Tune Final
  22Ne2+ 20Ne2+ 20Ne1+   25Mg1+ 20Ne1+   20Ne1+ 20Ne1+
IOS:BIAS:VOL.VAL 22440 20400 40800   51000 40800   40800 40800
IOS:EE:VOL.VAL 1072 975 1949     3064   3064 1419
IOS:EESS:VOL.VAL 1810 1645 3290     0   0 0
IOS:XCB1:VOL.VAL 225 205 409     0   0 500
IOS:YCB1:VOL.VAL 268 244 487     0   0 140
IOS:CCB1:VOL.VAL 500 455 909     0   0 500
IOS:B1A:POS:VOL.VAL 3301 3001 6001     5693   5693 5933
IOS:B1A:NEG:VOL.VAL 3845 3496 6991     5693   5693 5933
IOS:XCB1AW:VOL.VAL 1658 1507 3014     4362   4362 3660
IOS:XCB1AE:VOL.VAL 2242 2038 4076     4362   4362 3660
IOS:YCB1A:VOL.VAL 412 375 749     0   0 340
IOS:Q1:POS:VOL.VAL 1215 1104 2208   -2425 -1940   0 1113
IOS:Q1:NEG:VOL.VAL 1215 1104 2208   -2425 -1940   0 1113
IOS:Q2:POS:VOL.VAL 148 134 269   -1115 -892   1428 892
IOS:Q2:NEG:VOL.VAL 148 134 269   -1115 -892   1428 892
IOS:Q3:POS:VOL.VAL 786 715 1429   0 0   2570 0
IOS:Q3:NEG:VOL.VAL 786 715 1429   0 0   2570 0
IOS:YCB3:VOL.VAL 397 361 721     0   0 500
IOS:MB:CUR.VAL 148 135 270     280   280 277
IOS:YCB4:VOL.VAL 316 287 575     0   0 470
IOS:CCB4:VOL.VAL 300 273 545     0   0 300
IOS:Q4:POS:VOL.VAL 1384 1258 2516   1333 1067   3392 1067
IOS:Q4:NEG:VOL.VAL 1384 1258 2516   1333 1067   3392 1067
IOS:Q5:POS:VOL.VAL 1254 1140 2280   0 0   2232 0
IOS:Q5:NEG:VOL.VAL 1254 1140 2280   0 0   2232 0
IOS:Q6:POS:VOL.VAL 0 0 0   3225 2580   0 2580
IOS:Q6:NEG:VOL.VAL 0 0 0   3225 2580   0 2580
IOS:YCB6:VOL.VAL 290 264 527     0   0 300

Saved tunes: 100518_1113.snapiosfc6 (strict) & 100518_1128.snapiosfc6 (tweaked). Emittance scan attached.

At noon, beam handed over to Sophia. She has questions about the defeats associated with the Q3 failure last year. Checking... done.

Summary of Q1/2/3 wiring status right now:

  • Defeat remains on Q1.
  • Q1+/- cables swapped at power supplies.
  • Q2 output is normal (+ drives L/R and - drives T/B) and is opposite to Q1 and Q3.
  • Q3 output is normal (+ drives T/B and - drives L/R).
  • All wiring at DBs is normal.

Sophia is continuing her tuning using IOS tune as provided.

Later... Sophia reports that this beam transports nicely. That said, the IOS tune is a little different now. Compare attached below.

Attachment 1: Picture_7.png  45 kB  | Hide | Hide all
Picture_7.png
Attachment 2: grab.D19916.png  19 kB  Uploaded Tue May 18 12:36:56 2010  | Show | Hide all
Attachment 3: grab.l19920.png  15 kB  Uploaded Tue May 18 12:37:15 2010  | Show | Hide all
Attachment 4: grab.w19925.png  14 kB  Uploaded Tue May 18 12:37:29 2010  | Show | Hide all
Attachment 5: grab.z19931.png  18 kB  Uploaded Tue May 18 12:37:42 2010  | Show | Hide all
Attachment 6: grab.r19947.png  17 kB  Uploaded Tue May 18 12:38:22 2010  | Show | Hide all
Attachment 7: Picture_13.png  61 kB  Uploaded Tue May 18 15:27:23 2010  | Show | Hide all
Attachment 8: Picture_14.png  44 kB  Uploaded Tue May 18 15:28:19 2010  | Show | Hide all
ELOG V2.9.2-2455