OLIS Logbook General
  General  Not logged in ELOG logo
Message ID: 25     Entry time: Fri Jun 19 11:59:49 2009
Author: Damien Gallop 
Type: Routine 
Category: General 
Subject: 16On+ emittance scans continue 

Keerthi developed a nice 16O7+ beam to FC6 last night. Beam current is about 3nA presently. Here is the first emittance scan from 11:05 today. A little spotty, but it's there. Higher resolution scan at 13:58 follows.

The third plot at 16:12 is 16O6+.

The fourth plot at 17:05 is a 16O5+ scan. However, the emittance rig stopped scanning at position #50, and is frozen at position #0 now. The operators are looking into it, and will reboot IOSIOC. I am ready to restore optics. Later... reboot and restore went well. Continue emittance scans.

The fifth plot at 18:36 is a higher res 16O5+ scan.

The sixth plot at 18:52 is 16O4+ and friends.

The seventh plot at 19:12 is 16O3+. It does not compare well with yesterday's scan of the same beam. Note that recovery from yesterday's IOSIOC reboot required a retuning effort. The source RF was changed in the interim also.

The eigth plot at 19:34 is 16O2+ and friends.

The ninth and final (for tionight) plot at 19:53 is 16O1+ and friends.

Attachment 1: grab.P23959.png  20 kB  Uploaded Fri Jun 19 16:24:04 2009  | Show | Show all
Attachment 2: grab.w23965.png  17 kB  Uploaded Fri Jun 19 16:24:25 2009  | Show | Show all
Attachment 3: grab.h23769.png  22 kB  Uploaded Fri Jun 19 16:28:36 2009  | Show | Show all
Attachment 4: grab.b23818.png  16 kB  Uploaded Fri Jun 19 16:29:04 2009  | Show | Show all
Attachment 5: grab.H24473.png  20 kB  Uploaded Fri Jun 19 17:17:41 2009  | Show | Show all
Attachment 6: grab.C24485.png  17 kB  Uploaded Fri Jun 19 17:17:58 2009  | Show | Show all
Attachment 7: grab.j19138.png  20 kB  Uploaded Fri Jun 19 18:41:08 2009  | Show | Show all
Attachment 8: grab.x19145.png  14 kB  Uploaded Fri Jun 19 18:41:24 2009  | Show | Show all
Attachment 9: grab.u19617.png  20 kB  Uploaded Fri Jun 19 19:38:47 2009  | Show | Show all
Attachment 10: grab.K19622.png  14 kB  Uploaded Fri Jun 19 19:39:01 2009  | Show | Show all
Attachment 11: grab.j19761.png  21 kB  Uploaded Fri Jun 19 19:55:51 2009  | Show | Show all
Attachment 12: grab.V19766.png  14 kB  Uploaded Fri Jun 19 19:56:04 2009  | Show | Show all
Attachment 13: grab.O19941.png  22 kB  Uploaded Fri Jun 19 20:15:25 2009  | Show | Show all
Attachment 14: grab.w19946.png  14 kB  Uploaded Fri Jun 19 20:16:04 2009  | Show | Show all
Attachment 15: grab.M20127.png  23 kB  Uploaded Fri Jun 19 20:38:27 2009  | Show | Show all
Attachment 16: grab.i20132.png  14 kB  Uploaded Fri Jun 19 20:38:43 2009  | Show | Show all
Attachment 17: grab.T20289.png  26 kB  Uploaded Fri Jun 19 20:56:43 2009  | Hide | Show all
grab.T20289.png
Attachment 18: grab.X20295.png  14 kB  Uploaded Fri Jun 19 20:57:01 2009  | Show | Show all
ELOG V2.9.2-2455