OLIS Logbook General
  General  Not logged in ELOG logo
Message ID: 223     Entry time: Tue Feb 2 10:06:41 2010
Author: Damien Gallop 
Type:  
Category:  
Subject: Supernanogan development wind-up 

We ran 32S5+ overnight. Keerthi has been working with the new surface source oven for the last couple of weeks. His results to come. Meanwhile, here are a stripchart of overnight beam plus a few panels after my tweaking. Slits are at 5mm position.

Observations:

  • The heater responds smoothly in 0.1A steps.
  • There is an optimal heater setting; more is not necesaarily more.
  • As always, there are several RF resonances within a range.
  • Higher resonance produces more beam but less stable.
  • Lower resonance produces less beam but more stable.
  • Optimal heater loading technique and current setting will require further study.

Save: 100202_1000.snapiosfc6

Last stripchart is FC6 starting a couple of minutes before shutting off the heater.

Power down everything around 17:30, and turn off IOS turbos. I have left IOS:IV0 open to ensure the intermediate section gets vented before the cart is removed. I am leaving the MCIS turbos on for now,. to continue pumpimg residual sulphur.

Attachment 1: grab.U23715.png  13 kB  | Show | Hide all
Attachment 2: grab.u23727.png  25 kB  | Show | Hide all
Attachment 3: grab.s23853.png  16 kB  | Show | Hide all
Attachment 4: grab.w23857.png  25 kB  | Hide | Hide all
grab.w23857.png
Attachment 5: grab.b23861.png  11 kB  | Show | Hide all
Attachment 6: grab.a24018.png  25 kB  | Show | Hide all
Attachment 7: grab.x24022.png  14 kB  | Show | Hide all
Attachment 8: grab.U24026.png  14 kB  | Show | Hide all
Attachment 9: grab.v24981.png  18 kB  Uploaded Tue Feb 2 17:11:50 2010  | Show | Hide all
ELOG V2.9.2-2455