OLIS Logbook General
  General  Not logged in ELOG logo
Message ID: 220     Entry time: Wed Jan 13 18:16:22 2010
Author: Damien Gallop 
Type:  
Category:  
Subject: OLIS development with MWS at 28keV 

We will be delivering a 28keV beam to the tuning boys tomorrow for further diagnosis of the 8pi line. In anticipation, I restarted the MWS with 20Ne1+ beam. With slits out, there are around 2uA on FC6. Emittance scan of current tune below.

Same tune again with slits in a 1mm, emittance scan attached.

Gas flow presently at 0.5ccm. I will lower it slightly, as IOS pressure is a little high.

Save: 100113_1830.snapiosfc6

Attachment 1: grab.M10333.png  25 kB  | Show | Show all
Attachment 2: grab.r10347.png  14 kB  | Show | Show all
Attachment 3: grab.R10351.png  14 kB  | Show | Show all
Attachment 4: grab.z10403.png  15 kB  | Show | Show all
Attachment 5: grab.l10407.png  15 kB  | Show | Show all
Attachment 6: grab.f10390.png  17 kB  | Show | Show all
ELOG V2.9.2-2455