136
Thu Jul 20 00:52:13 2006
Doug Preddy
Quench Recovery
T1 frozen
T1 will not spin up. Warming up cold box.
137
Thu Jul 20 02:59:06 2006
Doug Preddy
Quench Recovery
T1 still not starting
I will leave the cold box to warm overnight
and try it again in the morning.
138
Thu Jul 20 08:18:31 2006
Doug Preddy
Quench Recovery
T1 started
Started flow to turbines. Both started. T1
seems a bit slow. HIC110 at 0.85
SI110 = 4100.
143
Fri Jul 21 07:39:37 2006
Doug Preddy
Quench Recovery
Cool down continues
Raised PIC229 to 11Bar. Started to close HIC155.
Cooling rates improve.
144
Fri Jul 21 14:08:04 2006
Doug Preddy
Quench Recovery
switch to series mode
Coils temps <10K.Switching to series mode.
146
Fri Jul 21 23:36:21 2006
Doug Preddy
Quench Recovery
Final cooldown problems
80K shield is down to <60K Liquid level not
building. Power leads rippling
and warming. T1 inlet 85K with 10%heater
148
Fri Jul 28 20:39:40 2006
Doug Preddy
Quench Recovery
Restarting refrigerator
Solenoid quenched at about 6:00 tonight.
I restarted the compressor, then the cold
box and turbines. When cold box
149
Sat Jul 29 05:30:28 2006
Doug Preddy
Quench Recovery
switched to series mode
Temps bottomed out at ~16K. Switching to series
mode.
150
Sat Jul 29 09:38:06 2006
Doug Preddy
Quench Recovery
power leads cooled
opened power lead flow about 40 minutes ago.
~12K will let them stablize.
LHE level >20%
151
Tue Aug 8 07:27:49 2006
Doug Preddy
Quench Recovery
Solenoid Quench at about 6:00 this morning
No indication of problem. Turbines still running,
but no flow to solenoid.
Started flow. Solenoid ~20K.
154
Wed Aug 9 07:50:49 2006
Doug Preddy
Quench Recovery
Switched to series mode.
Cool down continues.
155
Thu Aug 10 08:33:44 2006
Doug Preddy
Normal Running
Running low on helium
Temperture okay, but there are fluctuation
in the power leads. PIC229 is
trying to charge. The buffer tank pressure
158
Tue Aug 15 08:45:56 2006
Doug Preddy
Quench Recovery
restarted the compressor
Solenoid tripped off Sunday. Restarted compressor
and cool down of cold box.
160
Thu Aug 17 08:04:44 2006
Doug Preddy
Quench Recovery
Solenoid tripped at about 3:00 this morning
restarting system.
Compressor would not start. Idid not see
anything that would not let it
162
Wed Oct 4 07:29:04 2006
Doug Preddy
Start Up
Starting cool down
Started compressor yesterday with flow through
the purifier overnight.
Starting tubines this morning in parallel
164
Thu Oct 5 10:26:26 2006
Doug Preddy
Start Up
switched to parallel cold return
165
Thu Oct 5 11:51:53 2006
Doug Preddy
Start Up
Adde 2 bottles UHP Helium
Valved off purifiers, but left LN2 on.
166
Thu Oct 5 14:53:54 2006
Doug Preddy
Start Up
Switched to series mode
173
Thu Oct 26 08:18:10 2006
Doug Preddy
Quench Recovery
switched to series mode
Switched to series mode at about 7:45.
174
Thu Oct 26 11:45:22 2006
Doug Preddy
Quench Recovery
Solenoid cold
power leads cold 50% liquid.
Turning on power supply