M9sol Logbooks Solenoid Daily log
  Solenoid logbook, Page 14 of 15  ELOG logo
ID Date Authordown Operational Mode Subject Text Attachments
  261   Fri Sep 26 09:50:18 2008 Doug PreddyQuench Recoverystarted flow in parallel cold return mode    
  262   Sun Oct 5 11:12:48 2008 Doug PreddyNormal RunningM9B:V1 interlocks and a IOC crashM9A:V1 was removed this shutdown. It's "in"
limit is required to allow M9B:V1 to be opened.
I have bypassed the interlocks on M9B:V1
  
  263   Sun Oct 5 18:54:27 2008 Doug PreddyQuench RecoverySolenoid Quench ~16:30Restarted compressor and flow to coldbox by
18:30
  
  264   Wed Nov 5 16:33:52 2008 Doug PreddyNormal Runningsbplc light outOn main menu the sbplc light was black. All
vacuum systems looked good, but there was
no control of any device. Jane reset the
  
  265   Wed Dec 10 15:41:04 2008 Doug PreddyShut Downshuttting down solenoidshuttting down solenoid for winter shutdown.   
  266   Wed Dec 10 15:44:58 2008 Doug PreddyMaintenanceRepairs to solenoid power supplyKlaus and company pulled the ramp rate card
out of the solenoid power supply. Operational
checks were done and the rate switch was
  
  267   Wed May 27 08:06:00 2009 Doug PreddyQuench RecoverySolenoid quenched at 5:00The solenoid quenched at 5:00 this morning
due to power lead temps. The temps started
oscillating about 10 minutes before the trip.
  
  268   Wed May 27 13:37:22 2009 Doug PreddyQuench Recoveryswitch to series modeSwitched to series mode at ~11:00. Built
liquid to 55% by 13:30. Started flow to the
power leads.
  
  269   Wed May 27 15:01:34 2009 Doug PreddyQuench Recoverypower leadsPower leads are cold. There is still a
small ripple. The power supply can be ramped
up as soon as the ripples die out.
  
  270   Fri Jul 10 00:34:03 2009 Doug PreddyQuench Recoverysolewnoid quench due to power bumpSolenoid quench due to power bump caused
by an airplane crash in Richmond at ~ 22:00.
Compressor off. Water pump off. Restarted
  
  271   Fri Jul 10 01:10:59 2009 Doug PreddyQuench Recoveryswitch to parallel warm return    
  272   Tue Jul 14 15:28:36 2009 Doug PreddyQuench RecoverySolenoid ramped upThe solenoid is cold and I have started
to ramp up the power supply. Some slight
ripples in the power leads, but they are
  
  273   Mon Oct 5 11:54:58 2009 Doug PreddyNormal RunningSwitched TIC121 into auto mode    
  274   Wed Mar 24 08:30:33 2010 Doug PreddyStart UpStart upCompressor started yesterday afternoon.
Pumping out solenoid overnight. Cold box
vacuum good. circulating helium to solenoid
  
  276   Thu Apr 1 11:57:55 2010 Doug PreddyStart Upstarted flow to power leadsSolenoid cold. Buffer tank pressure ~3psi,
so Kevin will add a bottle of helium. Started
flow to power leads at 11:45
  
  277   Fri Apr 9 07:34:55 2010 Doug PreddyQuench Recoveryswitched to parallel cold returnSwitched to parallel cold return at about
7:30 this morning
 
  
  278   Fri Apr 9 16:07:28 2010 Doug PreddyStart Upflow to power leads started    
  279   Mon May 3 07:49:54 2010 Doug PreddyQuench RecoverySolenoid quench SaturdaySolenoid quenched at ~13:30 Saturday. Kevin
came in later in the day to recover it. System
was in all around mode, no flow to solenoid.
  
  280   Thu May 13 07:39:55 2010 Doug PreddyQuench Recoverysolenoid quench last nightSolenoid quenched on power lead temps last
evening. I am recovering it in parallel cold
return mode. C12~60K C1~50K.
  
  281   Thu May 13 14:37:13 2010 Doug PreddyQuench Recoveryswitching to series mode.    
ELOG V2.9.2-2455