M9sol Logbooks
Solenoid
Daily log
Solenoid logbook, Page 14 of 15
New
|
Reply
|
Find
|
Delete
|
Last day
|
Help
|
Config
Full
| Summary |
Threaded
286 Entries
Goto page
Previous
1
,
2
,
3
...
13
, 14,
15
Next
All
ID
Date
Author
Operational Mode
Subject
Text
261
Fri Sep 26 09:50:18 2008
Doug Preddy
Quench Recovery
started flow in parallel cold return mode
262
Sun Oct 5 11:12:48 2008
Doug Preddy
Normal Running
M9B:V1 interlocks and a IOC crash
M9A:V1 was removed this shutdown. It's "in"
limit is required to allow M9B:V1 to be opened.
I have bypassed the interlocks on M9B:V1
263
Sun Oct 5 18:54:27 2008
Doug Preddy
Quench Recovery
Solenoid Quench ~16:30
Restarted compressor and flow to coldbox by
18:30
264
Wed Nov 5 16:33:52 2008
Doug Preddy
Normal Running
sbplc light out
On main menu the sbplc light was black. All
vacuum systems looked good, but there was
no control of any device. Jane reset the
265
Wed Dec 10 15:41:04 2008
Doug Preddy
Shut Down
shuttting down solenoid
shuttting down solenoid for winter shutdown.
266
Wed Dec 10 15:44:58 2008
Doug Preddy
Maintenance
Repairs to solenoid power supply
Klaus and company pulled the ramp rate card
out of the solenoid power supply. Operational
checks were done and the rate switch was
267
Wed May 27 08:06:00 2009
Doug Preddy
Quench Recovery
Solenoid quenched at 5:00
The solenoid quenched at 5:00 this morning
due to power lead temps. The temps started
oscillating about 10 minutes before the trip.
268
Wed May 27 13:37:22 2009
Doug Preddy
Quench Recovery
switch to series mode
Switched to series mode at ~11:00. Built
liquid to 55% by 13:30. Started flow to the
power leads.
269
Wed May 27 15:01:34 2009
Doug Preddy
Quench Recovery
power leads
Power leads are cold. There is still a
small ripple. The power supply can be ramped
up as soon as the ripples die out.
270
Fri Jul 10 00:34:03 2009
Doug Preddy
Quench Recovery
solewnoid quench due to power bump
Solenoid quench due to power bump caused
by an airplane crash in Richmond at ~ 22:00.
Compressor off. Water pump off. Restarted
271
Fri Jul 10 01:10:59 2009
Doug Preddy
Quench Recovery
switch to parallel warm return
272
Tue Jul 14 15:28:36 2009
Doug Preddy
Quench Recovery
Solenoid ramped up
The solenoid is cold and I have started
to ramp up the power supply. Some slight
ripples in the power leads, but they are
273
Mon Oct 5 11:54:58 2009
Doug Preddy
Normal Running
Switched TIC121 into auto mode
274
Wed Mar 24 08:30:33 2010
Doug Preddy
Start Up
Start up
Compressor started yesterday afternoon.
Pumping out solenoid overnight. Cold box
vacuum good. circulating helium to solenoid
276
Thu Apr 1 11:57:55 2010
Doug Preddy
Start Up
started flow to power leads
Solenoid cold. Buffer tank pressure ~3psi,
so Kevin will add a bottle of helium. Started
flow to power leads at 11:45
277
Fri Apr 9 07:34:55 2010
Doug Preddy
Quench Recovery
switched to parallel cold return
Switched to parallel cold return at about
7:30 this morning
278
Fri Apr 9 16:07:28 2010
Doug Preddy
Start Up
flow to power leads started
279
Mon May 3 07:49:54 2010
Doug Preddy
Quench Recovery
Solenoid quench Saturday
Solenoid quenched at ~13:30 Saturday. Kevin
came in later in the day to recover it. System
was in all around mode, no flow to solenoid.
280
Thu May 13 07:39:55 2010
Doug Preddy
Quench Recovery
solenoid quench last night
Solenoid quenched on power lead temps last
evening. I am recovering it in parallel cold
return mode. C12~60K C1~50K.
281
Thu May 13 14:37:13 2010
Doug Preddy
Quench Recovery
switching to series mode.
Goto page
Previous
1
,
2
,
3
...
13
, 14,
15
Next
All
ELOG V2.9.2-2455