ID Date Author Operational Mode Subjectdown
  110   Mon Oct 31 07:48:57 2005 Willy AnderssonQuench Recoverywhat a fine entry
Keep IT safe boys
  196   Wed May 16 10:02:35 2007 Doug PreddyMaintenancewarming up power leads
Power lead temps have been slowly increasing over the last wekk. I ramped 
the solenoid down and am warming the power leads to >80k.
  56   Thu Oct 7 13:33:20 2004 Doug PreddyStart Upturned off purifier
turned off purifier
  84   Wed Nov 24 14:58:42 2004 Doug PreddyQuench Recoverytoday
Came in this morning to find the helium return line to the buffer tank 
frosted up. MV51 has been stuck open the whole time. That exlains the 
cooldown rate and other problem. Cycled MV51 a few times and it now seems 
closed. Switched back to parallel cold return this moring at 8:00. Rates 
are much better. The E-log was also down this morning.
  95   Wed Jun 1 23:48:02 2005 Doug PreddyQuench Recoverythe first quench
I recieved a call from ops at 22:00 tonight that the solenoid had alarmed. 
I came in and found a cold box fault, with the compressor tripped off. I 
was unable to restart the compressor. I cleared the cryostat quench and 
compressor trips. The system looked as though it was ready to start. I 
pushed the compressor "ON" button, but as soon as the main contactor 
closed, the compressor tripped again. After a few trys and a bit of 
searching, I tried resetting the compressor over-pressure switch. That 
allowed me to restart the compressor. Once the high pressure comes up I'll 
start flow to the turbines.
  133   Thu Jul 6 15:00:15 2006 Doug PreddyNormal Runningtest
  134   Thu Jul 6 15:04:17 2006 Doug PreddyNormal Runningtest
test
Attachment 1: M9daily log070306.XLS
  206   Wed Jul 4 11:13:12 2007 Doug PreddyQuench Recoverytest
This is a test to make sure the e-mail works.
  100   Thu Jun 9 08:56:10 2005 Doug PreddyQuench Recoverysystem back on
The compressor was restarted and the solenoid is cooling (sort of) in 
parallel cold return.
  281   Thu May 13 14:37:13 2010 Doug PreddyQuench Recoveryswitching to series mode.
  247   Thu Apr 17 13:52:25 2008 Doug PreddyStart Upswitched to series mode at 9:30 this morning
switched to series mode at 9:30 this morning. Added two bottles of helium gas. Started flow to power leads.
  71   Thu Oct 21 15:41:29 2004 Doug PreddyStart Upswitched to series mode
  149   Sat Jul 29 05:30:28 2006 Doug PreddyQuench Recoveryswitched to series mode
Temps bottomed out at ~16K. Switching to series mode.
  173   Thu Oct 26 08:18:10 2006 Doug PreddyQuench Recoveryswitched to series mode
Switched to series mode at about 7:45.
  228   Tue Oct 9 13:16:44 2007 Doug PreddyQuench Recoveryswitched to series mode
  231   Fri Nov 9 07:37:44 2007 Doug PreddyQuench Recoveryswitched to series mode
switched to series mode.
  236   Mon Nov 19 04:30:47 2007 Doug PreddyQuench Recoveryswitched to series mode
  81   Tue Nov 23 15:10:06 2004 Doug PreddyQuench Recoveryswitched to parallel cold return mode
  70   Thu Oct 21 07:16:35 2004 Doug PreddyStart Upswitched to parallel cold return
  104   Tue Jun 14 23:01:22 2005 Doug PreddyQuench Recoveryswitched to parallel cold return