> Last night the power supply was ramping up at a very slow rate. This > morning it was energized,but with no current even though the limit was set > to 500 amps. Klaus R. found the pot. that set the current limit was bad. > Repaired it. First try at ramping caused a voltage imbalance and a quench > I. After a quick recovery, the second try was successfull. Solenoid ramping > to 500 amps at a good rate.