M9sol Logbooks
Solenoid
Daily log
Solenoid logbook
Fields marked with
*
are required
Entry time:
Wed Jan 15 13:46:05 2025
Author
*
:
- please select -
Doug Preddy
Curtis Ballard
Kevin Trithardt
David Kishi
Experimentor
Other
Operational Mode:
- please select -
Normal Running
Quench Recovery
Start Up
Shut Down
Maintenance
Other
Subject
*
:
> Last night the power supply was ramping up at a very slow rate. This > morning it was energized,but with no current even though the limit was set > to 500 amps. Klaus R. found the pot. that set the current limit was bad. > Repaired it. First try at ramping caused a voltage imbalance and a quench > I. After a quick recovery, the second try was successfull. Solenoid ramping > to 500 amps at a good rate.
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
ELOG V2.9.2-2455