> PIC 229 was down to 10.8 bar this morning. PIC 229 was trying to open CV211 > to charge the system. I realized that in restoring the control to CV211 I > did not get the wire into the connector properly. Went back up to the > compressor building and reconnected the control wire to CV211. pressure is > back to 11 bar. TI121, LHE in and liquid level ripples are now all reduced. > > System was ramped up to 500 amps yesterday at 14:00