Subject
*
:
> Machine trip just as I was exiting the TRIUMF gate. QRL said cold box fault > as did red lite on compressor. At cold box panel all turbine red lites were > on and compressed air failure lite was on. But there was no problems with > compressed air. On fist trip logger LED # 8 and 16 were lit. Restarted > compressor then start flow to cold box, start turbines, start // warm > return until temps returning back from solenoid were <= TIC121 then > switched to //cold return mode. Opened cv155 to 0.88 > Solenoid temps at 24K and starting to trend down.