M9sol Logbooks
Solenoid
Daily log
Daily log
Fields marked with
*
are required
Entry time:
Fri Dec 12 09:01:52 2025
Author
*
:
Type:
- please select -
Routine
Other
Category:
- please select -
General
Other
Subject:
> COMPRESSOR BUILDING > > 1 Oil cooler water inlet temp. (28) > > 2 Oil cooler water exit temp. (30) > > 3 Gas cooler water exit temp. (25) > > 4 Suction gas temp. (23) > > 5 Discharge gas temp. (82) > > 6 Final gas temp. (23) > > 7 Oil temp. (40) > > 8 Suction gas press. (0.1) > > 9 Discharge press. (10.8) > > 10 Final gas press. (10.5) > > 11 Oil press. (13.0) > > 12 Oil filter out press. (10.2) > > 13 Compressor current (270) > > 14 Oil pump current (5.1) > > 15 Hours (????) > > 16 Warning lights (ok) > > 17 Oil level (9.0) > > 18 Gas cooler water inlet temp. (72) > > 19 Gas cooler water flow (16) > > 20 Oil cooler water flow (135) > > 21 Water pump pressure (65) > > 22 Water pump condition (ok) > > 23 Cu. non-active water flow (165) > > 24 PI9 Buffer tank pressure (15) > > 25 PI218 Low pressure (3.0) > > 26 PI229 High pressure (145) > > 27 PI296 Inlet press. (147) > > 28 Air compressor condition (ok) > > SULZER CONTROL PANEL > > 29 PI 110-1 T1 inlet press. (9.4) > > 30 PI 120-1 T2 inlet press. (4.0) > > 31 HIC 106 Turbine inlet press. (9.9) > > 32 TI 148 Mu1 supply temp. (4.05) > > 33 TI 149 Mu1 supply temp. (4.05) > > 34 HIC 143 Mu1 supply (9.9) > > 35 PI 143 Mu1 supply pressure (10.4) > > 36 HIC 151 Mu1 warm return (0.0) > > 37 HIC 104 Shield bypass (0.55) > > 38 PDI 104 Shield press. drop (0.8) > > 39 HIC 145 Mu1 JT valve (0.0) > > 40 HIC 144 Mu1 return (9.9) > > 41 SI 110 T1 speed (4500) > > 42 SI 120 T2 speed (3200) > > 43 Hic 110 T1 brake (0.7) > > 44 HIC 120 T2 brake (0.75) > > 45 HIC 146 Mu2 supply (0.0) > > 46 PI 146 Mu2 supply press. (8.2) > > 47 HIC 153 Mu2 warm return (0.0) > > 48 HIC 142 power leads supply (0.51) > > 49 HIC 147 Mu2 JT valve (0.45) > > 50 HIC 155 JT bypass (0.0) > > 51 HIC 105 shield heater (0.56) > > 52 Shield heat load % (40) > > COMPRESSOR DISCHARGE PRESSURE PIC 229 > > 53 Auto/ manual (auto) > > 54 Set point (green) (11) > > 55 Reading (red) (11) > > 56 Output (upper) (0.6) > > 57 Output (lower) (0.6) > > COMPRESSOR SUCTION PRESSURE PIC 218 > > 58 Auto/ manual (auto) > > 59 Set point (green) (1.1) > > 60 Reading (red) (1.1) > > 61 Output (upper) (0.6) > > 62 Output (lower) (0.6) > > T2 OUTLET TEMPERATURE TIC 121 > > 63 Auto/ manual (auto) > > 64 Set point (green) (4) > > 65 Reading (red) (4.3) > > 66 Output (upper) (0.45) > > 67 Output (lower) (0.45) > > LIQUID HELIUM VESSEL HEATER LIC 108 > > 68 Auto/ manual (auto) > > 69 Set point (green) (50) > > 70 Reading (red) (52) > > 71 Output (upper) (0.55) > > 72 Output (lower) (0.6) > > 73 Slide valve position (100) > > 74 Hours (????) > > 75 PI 108 Lhe vessel pressure (1.2) > > 76 Lhe vessel heater load (15) > > 77 Diffusion pump current (2.8) > > 78 PI 100 cold box inlet press. (10.5) > > 79 PI 130 cold box outlet press. (1.05) > > 80 TE 150 Mu1 supply (1.3) > > 81 TE 151 Mu1 return (1.0) > > 82 TE 152 Mu2 supply (-3.5) > > 83 TE 103 shield return (70) > > 84 TE 106 T1 inlet (73.0) > > 85 TE 107 Hx5 high press out (2.5) > > 86 TE109 Hx5 low press in (1.3) > > 87 TE 153 Mu2 return (0.5) > > 88 TE 130 low press. Outlet (285) > > 89 TE 102 Adsorber (83.0) > > 90 Vessel pressure Head 1 (0.0x10-4) > > 91 Backing pressure Head 2 (4.2x10-2) > > 92 Solenoid vacuum Head 3 (0.0x10-4) > > 93 BIG1 solenoid vacuum (3.5x10-7) > > 94 BIG2 solenoid backing (5.0x10-2) > > 95 Turbine 1 temp. (-20) > > 96 Turbine 2 temp. (-23) > > 97 Air pressure (95) > > 98 Solenoid current (???) > > SOLENOID GAUGE PACKAGE > > 99 PAI 1 (9.5) > > 100 PI 2 (7.7) > > 101 PI3 (7.5) > > 102 PAI 4 (6.0) > > 103 PI 5 (5.5) > > 104 PI6 (9.0) > > 105 Power lead flow positive (>250) > > 106 Power lead flow negative (>250) > > 107 Water pressure in (70) > > 108 Water pressure out (35)
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
ELOG V2.9.2-2455